WARNING: Disconnect the AC power before any work is done to any part of
the circuit ReVent is connected to. If you do not understand this warning,
seek the services of a qualified licensed electrician.
WARNING: Copper to copper only. Do not use aluminum wire.
WARNING: Follow all local electrical and safety codes, and NEC (National
Electrical Codes).
CAUTION: If your house wires do not match these colors, determine what
each house wire represents before connecting. You may need to consult a
qualified licensed electrician to determine this safely.
6.) Remove the electrical cover set screw and slide open the electrical enclosure.
Disconnect FAN motor from electrical enclosure.
remove
set screw
7.) Connect wiring using the provided WIRE NUTS. Match wire colors as shown:
line
ground
housing
ground
line in
neutral
neutral
17
slide
line in
FAN
FAN
unplug fan
connector
WIRE NUT
Qty:3