Activated
Carbon
Post-filter
Consumer
Troubleshooting
Guide
The activated carbon filter must be replaced when it is no longer effective in eliminating
odors. The life of the carbon filter will depend on the concentration of odors and
fumes in the air passing through the air cleaner. Under normal operating conditions,
the carbon filter should last from three to six months. The carbon filter must be in
place for the air cleaner to operate.
In the event that you experience problems with the operation of your air cleaner,
please . . .
Make sure electronic cell is clean, dry, and properly installed.
Make sure pre-filter and carbon filter are both properly installed.
Make sure the top cover is properly snapped in place.
Check fan motor and indicator lamp on all speed settings starting with low.
If your air cleaner still has any of the following problems, proceed step by step as
shown below until no further action needs to be taken.
PROBLEM 1 - Fan Off, Lamp Off
Make sure the supply cord is plugged into a standard household receptacle.
Make sure there is voltage to the receptacle by using any other electric device.
Make sure the carbon filter is in place.
Make sure the top access cover is properly in place in order to actuate the interlock
switch. The interlock switch is provided for consumer safety and should never be
bypassed.
No further corrective actions should be taken by the consumer. Return unit to
Regional Authorized Warranty Station for repair (see page 10.)
PROBLEM 2 - Fan On, Lamp Off
Allow the electronic cell to dry completely before reinstalling it into the unit.
Unplug the unit and check electronic cell to see if any of the collector plates are
touching. Gently straighten and evenly space the plates.
Check electronic cell to see if any of the ionizer wires are broken. See page 8 for
location. If broken wires are observed, no further corrective actions should be
taken by the consumer. Return unit to Regional C-90A Authorized Warranty Station
for repair.
PROBLEM 3 - Fan Off, Lamp On
This condition represents an unserviceable failure of the air cleaner. Return to
Regional Authorized Warranty Station for repair.
Page 7