2. Selecting the location
When selecting the location for the switch cabinet, the following must be taken into account:
The location must be protected from direct sunlight during the summer months.
The rear side of the cabinet must be installed with at least 10 cm clearance from the nearest wall.
The system generates noise! The air compressor located in the system generates a longer
continuous noise (comparable to a freezer or an oil heating fan).
The air hoses must be no longer than 20 metres.
The switch cabinet must not be installed in groundwater. This also applies to groundwater or
backwater that occurs only occasionally.
There must be a permanent power supply to the cabinet. Ensure that the cabinet is adequately fused
(16 A) and the power supply is fitted with isolator switch for repair & maintenance. Additional
electrical components & consumers should not be using the same fuse as they could cause power
failure and interfere with the cabinet operation.
The service duct/technical pipe is connected to the front of the switch cabinet. Additional service duct
connections are provided on the other sides of the cabinet in which a further opening can be made on
site.
2. Selecting the location