Broan FRESH IN FIN-6MD Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

4.1 AHU W
iring
AHU Wiring Options
CFIS
System
J4
Y
W
G
F
G
NC
COM
NO
R
C
Internal
Logic
Mandatory Installation Wiring
Optional Installation Wiring (Recommended if existing Y/W
connections are present at AHU)
FIN-6MD Hard Connections
5. SETTING UP THE UNIT
When powered ON, the FIN-6MD performs a 30-second booting sequence followed by a 30-minute period
where is stays OFF, but will activate if a heating or cooling call is sent to the AHU.
Refer to local building codes to determine the required airflow.
1.
Doublecheck the wiring, and turn power back ON to the AHU.
2.
Set the thermostat to send a heating or cooling call, or jump R and Y on the terminal block. This will
force the ventilation ON for at least 5 minutes.
3.
Measure the airflow.
If it needs adjustment, perform steps 4. If the airflow does not need adjustment, go to step 5.
4.
The damper is factory set to fully open position. To adjust it, set the left pot to DAMPER
ADJUSTMENT to start the AHU blower, and wait 5 seconds. The LED will blink continuously to
indicate the unit is in DAMPER ADJUSTMENT mode.
While measuring the airflow, adjust the damper using the RUN TIME % pot until you've reached the
desired value.
Damper
half open
5.
Select the desired mode according to the table and map in section 7.3. Doing so also saves the
damper adjustment made in the previous step if applicable.
6.
Set the RUN TIME % pot.
Run time % = Required Airflow
Measured Airflow
7.
Install the supplied cover to protect the adjustment pots and
prevent an accidental change of settings. Note that the hole may
be hidden by the label.
6. TESTING
When powered ON, the FIN-6MD performs a 30-second booting sequence followed by a 30-minute period
where it stays OFF, but will activate if a heating or cooling call is sent to the AHU.
6.1 B
(
loWer door test
force tHe dAmper closed
If the access to the integrated switch OR to the remote switch (if
applicable) is easy, set the integrated switch OR remote switch to
OFF.
If the access to the switch is not easy, such as in an attic:
1.
Turn OFF the power to the AHU at the service panel.
2.
Turn the power to the AHU back ON at the service panel.
3.
Wait 30 seconds for the booting sequence to execute.
4.
Make sure that the thermostat will not send a heating or cooling
call.
5.
Unit is OFF with its damper closed for 30 minutes, but will
activate if a heating or cooling call is sent to the AHU.
6.2 V
(
entilAtion test
forcing tHe Unit
1.
Turn OFF the power to the AHU at the service panel, and make sure that the integrated or remote switch
is set to ON.
2.
Turn the power back ON at the service panel.
3.
Wait 30 seconds for the booting sequence to execute.
4.
Set the thermostat to send a heating or cooling call, or jump R and Y on the terminal block. This will force
the ventilation ON for at least 5 minutes.
7. USER INFORMATION
7.1 i
ntegrAted And remote sWitcHes
This unit is equipped with an integrated ON/OFF switch. For more
convenience, your FIN-6MD can also be connected to a remote
switch.
To use a remote switch, disconnect the integrated switch and
connect the remote switch in the same manner that the integrated
one was connected.
7.2 U
s
i
ser
erVicing
nstrUctions
• Inspect the outdoor air intake at least once a year.
• These recommendations may change according to the environmental conditions in your area.
Thermostat
Y W G R C
Damper
fully open
Example : Run Time % = 60 CFM = 50%
120 CFM
)
Integrated switch
on):
Integrated switch
7.3 c
omfort
Should the air inside your house become too humid, or if such conditions want to be prevented, the operation
mode of your FIN-6MD can be changed from a Code-Compliant one (modes 1 and 2) to a Comfort Mode
(modes A to E). Refer to the map below to make the right choice.
When making such change, make sure to only change the Mode and to leave the Run time % as it was set by
AHU
your installer. If in doubt, refer to your HVAC contractor.
Y
W
G
R
1 - Ashrae 2010/IRC/IMC (factory set)
2 - Ashrae 2016/2019
C
A - Comfort mode Hot / Humid #1
B - Comfort mode Hot / Humid #2
C - Comfort mode Hot / Dry
D - Comfort mode Mixed / Humid
E - Comfort mode Mixed / Dry
*Refer to the label on the unit for the full limits table.
**As defined by the Department of Energy.
7.4 t
roUBlesHooting
A LED indicator is located to the right of the terminal block on the unit and communicates the different states
of the unit. Blinking patterns and ways to address them, if applicable, are as follows:
Sensor error
Damper error
Damper
adjustment mode
Learning mode
2
m
ode
Broan-NuTone LLC Hartford, Wisconsin
www.broan-nutone.com 800-558-1711
2 A B C
D
1
Damper
E
adjustment
MODE
(wait 5 sec.)
Refer to installation instructions
Selected mode*
for more details.
Zones 1-5
Zones 1-5
Zones 2A and 1
Zones 1 and 2A
Zone 2B
Zones 3A, 4A, 5A, 3C and 4C
Zones 3B, 4B and 5B
5A
5B
1 blink
Disconnect the terminal block, and connect again. If the error
persists, replace the unit.
2 blinks
Disconnect the terminal block.
Open unit (see image below).
Perform a visual inspection and remove any debris hindering
damper movement.
Close unit and put the terminal block back in place.
If error persists, replace the unit.
Continuous blink
This is normal while the unit is in adjustment mode.
1 s ON, 10 s OFF
This is normal. Will blink for 48 hours after being powered ON.
1- Set left pot to DAMPER
ADJUSTMENT.
40 5060 70
2- Use right pot to adjust
30
damper from fully
80
20
90
open to half open.
OFF
100
3- Set the required mode
RUN
to save damper setting.
TIME %
4- Set the RUN TIME% to
get the required
Climate Zones**
ventilation level.
Internal insulation
Cod
1- A
2- A
Com
A- H
B- H
C- H
D- M
E- M