Brief description

The
LIN parameter adapter facilitates the connection between the GEZE Service terminal ST 220 and IQ windowdrives:
FSE03
Slimchain, Powerchain, E 250 NT, E 90x, etc. As a result, the parameter setting for the drives is realised via the LIN bus.
Safety notices
To ensure personal safety, it is important to follow these safety instructions. These instructions must be kept.
Before installation, read and observe the enclosed safety notes.
X
Warranty claims require proper mounting, installation and maintenance in accordance with the manufacturer's specifications.
X
Only specialists who are authorised by GEZE are permitted to carry out installation, commissioning and maintenance
X
If unauthorised changes are made to the system, GEZE cannot be made liable in any way whatsoever for any resulting damages.
GEZE makes no guarantee for combinations with third-party devices.
X
Ensure that the connection to the mains voltage is only performed by an electrician, the mains connection and ground con-
X
ductor must be installed in accordance with DIN VDE 0100-610.
Observe the latest versions of guidelines, standards and country-specific regulations.
X
The
LIN parameter adapter must be protected from building dirt and water.
FSE03
X
Technical data
FSE03 LIN-Parameter adapter
GEZE Service terminal ST 220
Supply voltage
Induced current intake
IP rating
Protection rating
Ambient temperature
Connection cross-section: 24V supply + drives
Connection: ST 220
Dimensions
Colour
Connection 230 V AC Drives :
~
230 V AC
IQ windowdrive
Connection 24 V DC Drives :
IQ windowdrive
Connection 230 V AC / 24 V DC Drives
Connect FSE301 LIN cable with the FSE03 LIN parameter setting adapter via the terminals.
X
Connect FSE301 LIN cable to the drive.
X
Connect supply voltage 230 V AC / 24 V DC Green LED in the FSE03 LIN parameter adapter switches on.
X
Connect ST 220 to the FSE03 LIN parameter adapter via the connection cable (the ST220 display switches on).
X
Adjust settings on the drive through the ST 220 (*).
X
(*) The parameter functions of the service terminal ST 220 are contained in the data sheet ID 153523 of the GEZE commissioning case.
4
ID 179238
ID 087261
+ connection cable
24 V DC, ±25 %, SELV
12 mA
IP20
III
-5...+60 °C
3 x 0.75 mm² (A,B,L)
5-pole trough pin strip (PTR)
50 mm x 35 mm x 20 mm
RAL 7035
ws A gn L br B
FSE301 LIN-cable
L
L
S
B
B
A
A
+ -
24 V DC
terminals
FSE03 LIN- Parameter adapter
FSE03 LIN- Parameter adapter
ST 220
ST 220
connection cable
ST 220
ST 220
connection cable