Safety Precautions
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage
and insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small
animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around
the unit clean.
• The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper pipes that are
not thermally insulated.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Provide a logbook and machine card. In accordance with the applicable legislation, it may be necessary to provide a
logbook with the equipment containing at least: info on maintenance, repair work, results of tests, stand-by periods,...
• Also, at least the following information shall be provided at an accessible place of the system:
- instructions for shutting down the system in case of an emergency
- name and address of fire department, police and hospital
- name, address and day & night telephone numbers for obtaining service.
In Europe, EN378 provides the necessary guidance for this logbook.
• Sound pressure level is less than 70 dB(A).
• Only use accessories, optional equipment and spare parts made or approved by DAIKIN.
How to handle the unit
WARNING
Heat exchanger is sharp, use gloves when handling the unit to avoid injury.
Accessories
Accessories supplied with the outdoor unit:
(A) Installation manual + R32 manual
At the bottom of the packing case.
(D) Multilingual fluorinated greenhouse gases label
English
CAUTION
(C) Refrigerant charge label
Contains fluorinated greenhouse gases
1
GWP: 675