LARZEP, S.A. guarantees its products against all design and manufacturing defects for two years from the
date of purchase. This guarantee does not include the ordinary wear of both metal and non‐metal parts,
abuse, using the equipment beyond its rated capacity and any wear or damage incurred as a result of using
a hydraulic fluid which is not recommended by LARZEP, S.A.
Please note that if the equipment is disassembled or serviced by anyone other than an authorized service
dealer or by LARZEP, S.A., this guarantee is rendered null and void.
In the event of a warranty claim, return the equipment to LARZEP, S.A. or the authorized dealer which sold
you the hydraulic equipment. LARZEP, S.A. will repair or replace the faulty equipment, whichever is
deemed most appropriate. LARZEP, S.A. shall not be held liable for any consequential damages or losses,
which may occur as a result of faulty equipment.
The recorder is being used to record the pressure or temperature or a combination of two pressures, two
temperatures or one temperature and one pressure, in a process over a certain period of time. A mechanical
clockwork drives the chart. A disposable felt pen is mounted on the pointer arm. Read pressure is written on
the chart.
Recorders are available in 192x192mm and 280x280mm. Chart diameters are available in163mm, 223mm.
Depending on the model the recorder can be equipped with a start/stop button to operate the clockwork.
Wind up nut
Chart clip
Start‐stop switch
WARRANTY
DESCRIPTION
Chart clip
Driving shaft
3
Pen
Penarm
Zero‐adjustment