MTC500 – Flashing module
Technical specifications
Maximum power:
500VA 2,2A, in normal installations
300VA 1,3A, in installations in IP65
sealed boxes
Mains voltage:
230V~ - 50Hz
Temperature:
from -20°C to +40°C
Relative humidity:
from 0 to 99%
Dimensions:
40 x 40 x 12 mm [1.57 x 1.57 x 0.47"]
Wires:
110 mm x 1 mm
Wiring
The module is wired to the circuit in series. It may be
positioned either on the live or neutral or on the concerned
lighting circuit return line. Connect the control contact, if
applicable, as shown in the figure.
Operation
A free contact must be used to connect the coil to live for the MTC500 to flash. The light will stop flashing
when the contact is opened. In this manner, the device may be controlled by a timer, a switch or simply
connected in series in a circuit with the coil connected directly to live.
The period may be configured using a temporary pushbutton. The configuration set in this way will be stored
inside the module thus allowing the MTC to be installed in the chosen circuit.
Resistive
Min. power 5W - Max. power 500W
230V incandescent light bulbs
230V halogen light bulbs
Radiating elements and convectors
Inductive
Min. power 11VA - Max. power 500VA
Low voltage light bulbs (12V) with ferromagnetic transformer
Low voltage light bulbs (12V) with toroidal transformer
Generic motor, aerator or fan > 11VA
Fluorescent light bulbs with ferromagnetic ballast
Metal halide light bulbs
Capacitance
Min. power 11VA - Max. power 500VA
Low voltage light bulbs (12V) with electronic transformer
Standard energy-saving light bulbs
Dimmable energy-saving light bulbs
Fluorescent light bulbs with electronic ballast
230V LED light
12V LED with dimmable converter
Window shutter motors
At 230V or 12/24V
(1) It is advisable to use 2000 range devices if neutral is available
(2) Never mix ferromagnetic, electronic and toroidal transformers with 12V low voltage light bulbs
(3) Check compatibility. Connect from 1 to 3 CHR3W accessories (code 5454070) in parallel to the load
to prevent flickering
(4) Maximum power: 250VA
Customer Service: +39 011.23.39.810 - Export Dept. Phone: +39 011.24.00.250/256 -
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from date of manufacture. The material must be used according to the
instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, anomalous use or incorrect installation.
In all cases, the warranty only includes replacement of faulty products. No compensation for loss or damage may be claimed.
DS1054-005C
[4.5 ", AWG17]
2
COMPATIBLE LOADS
Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C
For technical information, go to www.yokis.com or call:
Fax: +39 011.24.00.296
Automatic contact:
timer, twilight sensor,
presence detector,
anemometer, etc.
(1)
(1)
(1)
(1,2)
(1,2)
(1)
(1,2)
(1,3,4)
(1,3,4)
(1,3,4)
(1,3,4)
(1,3,4)
P3
GB
Installation
Model
Flush-mounted
MTC500-E
B = White wire
V = Purple wire
O = Orange wire
Temporary
configuration
pushbutton
Flasher module period configuration
Number of
Presses (1)
Period
11
0.2 seconds
12
0.4 seconds
13 (*)
0.8 seconds
14
1.6 seconds
15
3.2 seconds
16
6.4 seconds
17
12.8 seconds
18
25.4 seconds
19
always on
21
Configuration lock
23 (*)
Configuration unlock
(1) short press sequences on a
temporarily connected pushbutton
(*) default value
Code
5454056