ST-8810
9
Technical data
Display:
Measure range:
Resolution:
Accuracy:
Emissivity settings:
Distance factor:
Sample rate:
Spectral response:
Power off:
Operating RH%:
Power supply:
Laser class:
Laser power:
Wave Length λ:
Operating temperature:
Weight:
Size:
Certificate:
EN
ST-8810
3 ½ digit (1999 count) LCD with backlight
–20 °C to +270 °C (–4 °F to +518 °F)
1 °C / 1 °F
±2 % of reading or ±2 °C (±4 °F)
•
Accuracy is given at 18 °C to 28 °C (64 °F to
82 °F), less than 80 % RH
•
Specified accuracy is valid for an emissivity of 0.95
0.95, fixed
distance : spot = approx. 8 : 1
approx. 1 s
6 – 14 µm
automatic shut off after 7 s inactivity
max. 80 % RH
9 V monobloc battery (6LR61)
2
1 mW (continuous radiation)
630 – 670 nm
0 °C to +50 °C (+32 °F to +122 °F)
180 g
159 x 76 x 57 mm
According to EN 60825-1:1994+A1+A2
Technical data
25