72
THERMEX Typhoon
GENEREL ADVARSEL
•
The hood and hob are developed and produced in accordance with
DS / EN 60335-1.
•
This product is only intended for use in private homes if it is used
for other purposes, the right of complaint lapses.
•
All installation must be carried out by a professionally trained te-
chnician in accordance with the instructions from Thermex Scan-
dinavia A / S (Thermex) and applicable legislation.
•
Thermex disclaims any responsibility for damage that has occur-
red as a result of incorrect installation, installation, use or incorre-
ct settings.
BEFORE INSTALLATION / COMMISSIONING
•
Check the hood for transport damage, faults and defects immedi-
ately upon receipt.
•
Transport damage is reported immediately upon receipt to the
transport company and Thermex.
•
Defects must be reported to Thermex within 8 days of receipt, and
no later than before installation / commissioning.
INSTALLATION
•
The hood is intended for operation at 230/400 Volt ± 10% ~ 50 HZ
according to EN 50160
•
Connect the product according to the instructions.
•
Do not connect power to the product until installation is complete.
•
The air must not be led from the hood into a pipe used for exhaust
from appliances using gas or other combustible materials, but
must have a separate exhaust.
•
National legislation on air emissions must be complied with.
•
Always use the original exhaust dimension. By reducing the
exhaust size, the performance decreases and the sound level in-
creases.
•
The exhaust from the hood to the open air should be as short as
possible, in order to get the greatest possible effect from the
hood.
•
The number of bends on the extractor should be minimized as
much as possible, in order to get the greatest possible effect from
the hood.
•
Thermex recommends that sound and condensation-insulated
flue hoses are always used when passing through unheated ro-
oms.
•
Thermex recommends that a muffler be used when using a flex
hose to minimize the sound level
•
When using a flex hose, it must always be ensured that it is fully
extended in order to minimize air resistance and thereby achieve
maximum suction power.
•
Different materials require different rawlplugs and screws. Use
rawl plugs and screws that fit the material the hood is to be moun-
ted in.
•
Failure to follow the instructions for mounting screws and
brackets may result in electric shock.