SICK TR4 Instrucciones De Operación página 143

Ocultar thumbs Ver también para TR4:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operating Instructions
TR4
Fig. 1: Response range
with M18 actuator
Fig. 2: Response range
with M30 actuator
8014465/2012-05-07
Subject to change without notice
Mounting
Off
Side approach
Off
Side approach
If the actuator moves laterally in relation to the surface of the sensor,
a minimum distance of 4 mm (with M18 actuator) or 7 mm (with
M30 actuator) must be maintained. This distance will prevent
premature triggering due to the side approach areas.
If necessary fit an additional protective stop for the moving part of
the guard.
Pay attention to the maximum tightening torque for fastening the
sensor and actuator of 2.3 Nm.
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Safe switch-on distance 15 mm
Off
On
Offset [mm]
Safe switch-on distance 25 mm
Off
On
Offset [mm]
GB
Chapter 4
Side approach
Side approach
143

Publicidad