Operating Instructions
TR4
Note
Notes
8014465/2012-05-07
Subject to change without notice
Commissioning
6.2.1
Teaching-in an actuator
Up to eight actuators can be taught-in on the TR4 Unique Coded. The
number of actuators that can still be taught-in is indicated by repeated
flashing of the Status/Diag LED on powering up the device (see Tab. 3).
How to teach-in an actuator:
Switch on the voltage supply of the sensor.
Move the actuator inside the response range of the TR4 Unique
Coded. The sensor then automatically starts the teach-in process.
The actuator must not be removed again from the response range
during the teach-in process. Otherwise the ability of the sensor to
teach-in further actuators will be deactivated.
Teach-in sequence
1.
Actuator inside the response range: The Status/Diag LED flashes
Green (1 Hz).
2.
Verifying the actuator: The Status/Diag LED flashes for 15 seconds
Green/red (1 Hz).
3.
Programming the sensor: The Status/Diag LED flashes for 15
seconds
Green/red (4 Hz).
4.
Programming complete: The Status/Diag LED flashes
(1 Hz) and indicates during this process the remaining number of
possible teach-in processes followed by a pause. This signal is
repeated for 15 seconds.
5.
Teach-in complete, sensor ready: The Status/Diag LED is illumina-
ted
Green.
To teach-in another actuator, place it in the response range of the
TR4 Unique Coded. The teach-in sequence is the same as during the
first teach-in.
Actuators taught-in previously are no longer accepted and can also
not be taught-in again.
Multicoded actuators cannot be taught-in.
A maximum of eight actuators can be taught-in on the TR4 Unique
Coded. Then the device is automatically locked for further teach-in
processes. The lock cannot be removed again.