Integral washbasin for feeder plug
electronic
Ref. 061418
Contents
- Sheathing for integral washbasin with feeder plug.
060606 - Detachable Breastplate to fi t into integral washbasin.
080418 - 1 box dispenser of gloves, tissue or towels.
460219 - Stainless steel 800 ml. soap dosing device.
060804 - Electronic kit for washbasins and sinks.
454202 - 2 ½" Valve with trough for 500mm sink.
409822 - Plastic nylon Fisher 6x30mm peg.
421038 - Plate thread bolt 22x4,8mm. DIN 7981 A2.
Assembly
Check the contents.
Avoid dirt in pipes and in the area before assembly.
If the plumbing is new, let the water fl ow.
When assembling, it is advisable to use special gloves not to get cuts on hands.
Use teffl on to seal connexions.
Pull out front door and remove the plastics from doors and washbasin.
Introduce the pipe in the upper orifi ce and fi x it the attached bolts ·
Open the control box and insert the supplied battery.
Connect the output of the non-return mixer to the input of the supplying knee ·
Connect the output of the supplying knee to the input of the control box ·
Connect the pipe of the control wire to the control box ·
Connect the hose to the control box ·
Fig. 1
Clamp the control box to the wall on a vertical position with the hose facing downwards
·
Fig. 1
Assemble the discharge valve ·
Fig. 3
Fix the washbasin on the wall ·
Fig. 4
You can now connect the water input and the discharge to the washbasin.
English
FRICOSMOS
Fig. 2
Fig. 1
Fig. 1
Fig. 1
Adjust the desired temperature by turning the non-return mixing crown.
Insert the Breastplate from the top of the pan fl ap, slide it along the guides and fasten
it with screws on the previously fi tted wall plugs.
Clamp the complements to the wall on the Breastplate with its corresponding screws.
Place the waste bag in the wastepaper bin of the door by sliding it upwards and then
pulling. Fasten the bag with the rubber band.
Use
To let the water run, put your hands near the pipe sensor.
To stop the fl ow of water, withdraw your hands.
Temperature can be adjusted with the non-return mixer handle.
To open the wastepaper bin, push its trap door with your hand.
Maintenance
Use only water and neutral soap when cleaning.
Wipe with a soft cloth.
Rinse with plenty of water.
Dry with a soft cloth.
Do not use acids or strong detergents and do not rub with a scourer or spatula.
Change the battery each 2-3 years depending on use.
Safety
If the sensor is activated for a minute the water supply will stop automatically for your
safety.
Other hazards have not been observed.
Available spares
060606 - Detachable Breastplate to fi t into integral washbasin.
080418 - 1 box dispenser of gloves, tissue or towels.
460219 - Stainless steel 800 ml. soap dosing device.
060804 - Electronic kit for washbasins and sinks.
461604 - 1/2" M-H-M non-return mixer.
454202 - 2 ½" Valve with trough for 500mm sink.
460822 - Sensor of battery operated electronic kit.
460820 - Control box of battery operated electronci kit.
460824 - Spare battery for battery kit.
All sizes are described in mms.