from the plate. Fit the input and output connecting pieces (G) and connect the device to the input
and output paths. The water will enter via the static mixer and leave the device again via the UV-C/
ozone housing. Turn on the pump and check the system for flow and for leaks. Turn on the UV-C
unit and the air pump.
DISASSEMBLY / MAINTENANCE
In the event of maintenance or disassembly of the equipment always disconnect the
electrical power!!
Switch off the power supply for the air pump, ozone device and the pond pump. The cover nut (H)
must be undone at the top from the ozone device to replace the lamp. Then carefully lift the lamp
a little. Undo the lamp from the lamp base and replace it if necessary. Refasten everything again
carefully in the original position.
The quartz glass (I) should be cleaned about once per year depending on the hardness of the water
and the pollution. To do this pull the glass carefully out of the housing using the pulling piece (J).
Clean the quartz glass using a suitable agent. Use a soft cloth to clean the glass and avoid scratches.
Do not touch the lamp with your hands; use a soft cloth to hold the lamp. If the lamp is touched
then it is advisable to clean it with a soft cloth and a little alcohol. Once all the parts have been put
back in their original positions then the pond pump can be started. Check the system for flow and
for leaks. Turn on the air pump and the UV-C unit.

TECHNICAL DATA

Ozone
UV-C Ozone lamp
Max pump
Max pressure
For the safety instructions and terms of guarantee we would like to
refer to the general UV-C manual from VGE International B.V.
0,6 gram
36 T5 HO VH 75W 4P-SE-BY1
20.000 l/h
1 Bar
XCLEAR AOP COMPACT OZONE + UV-C |