Instructions
Media converters connect two Ethernet networks over a longer distance using fiber optic cable.
For specifications, visit intellinetnetwork.com. Register your product at
register.intellinet-network.com/r/508322 or scan the QR code on the cover.
Features
• One 10/100 RJ45 port supporting a maximum distance of 100 m (300 ft.)
• One 1000Base-SX fiber SC single-mode port supporting a maximum distance of 20 km (12.4 mi.)
• IP40 slim-type metal housing to withstand harsh industrial conditions
• Option for DIN-rail installation
• Two redundant DC inputs (12 - 58 V) with I/O terminal block
Connections
Twisted Pair – RJ45
Connect the UTP port of the media converter to an
RJ45 port on the network (e.g., to an Ethernet switch).
Cat5e or better cabling is recommended.
Fiber Optic
As shown, two fiber optic cables need to be connected
between two ideally identical media converters.
Make a connection from Media Converter 1 TX to Media Converter 2 RX, and from Media Converter 1 RX to
Media Converter 2 TX. Maximum length and fiber cable specification depend on the model. (See Models.)
Front panel
Item
RJ45 Port
P — Power
O — Optical Fiber Port
A — Alarm
N — NMC
2
English
LED
Port activity
Speed
Power and power-
supply-under-voltage
alarm (priority of
under-voltage alarm is
higher than power LED)
Fiber port and power
supply overvoltage alarm
(priority for overvoltage
alarm is higher than fiber
port Link/Act LED)
Device alarm and data
transmission indicator
Management indicator
and data receiving
Fast Ethernet Industrial Media Converter
MEDIA CONVERTER 1
ETHERNET 1
TWISTED PAIR
Color
Status
Flashing
Sending or receiving data.
Green
On
Port is connected.
Off
Port is not connected.
On
100 Mbps speed.
Yellow
Off
10 Mbps speed.
Flashing
Equipment power supply is lower than the lower limit of the
every 1s
input range of DC 12 V, indicating an under-voltage alarm.
Green
On
Power channel is powered.
Off
Power channel is not powered.
Flashing
The power supply of the device exceeds the upper limit of the
every 0.5s
input range of DC 58 V, indicating an overvoltage alarm.
On
Fiber port is connected.
Green
Off
Fiber port is not connected.
Flashing
Sending or receiving data.
Console/RS232/RS485 port is sending data (LED
Flashing
flashes to the rhythm of data being sent).
Red
On
An issue has been detected (temperature, dying gasp, etc.).
Off
No alarm issue detected.
Console/RS232/RS485 port is receiving data (LED
Flashing
flashes to the rhythm of data being received).
Green
On
Module embedded and initialization is complete.
Off
No embedded module.
Example
TWISTED PAIR
TX
RX
RJ45
ETHERNET 2
OPTICAL FIBER
RJ45
TX
RX
MEDIA CONVERTER 2