INSTRUCTIONS
DESCRIPTION
The VEGA twilight switch permits the controlling of premises depending on the
prevailing light.
The device compares the surrounding light with the adjusted level; if it is less than
this level, it is activated after a delay time. When the light increases and reaches
the switch off level, it turns off after the delay time.
INSTALLATION
Note: the installation and fitting of electrical devices must be carried out by an
authorised fitter.
BEFORE BEGINNING THE INSTALLATION, DISCONNECT THE POWER SUPPLY.
The apparatus is internally protected against interferences from safety circuits.
However, some specially strong electromagnetic fields may cause an incorrect
functioning; therefore, it must not be installed near inductive fields (motors,
transformers, etc.)
FITTING AND CONNECTION
On a wall or support avoiding direct sunlight. Do not install in places where artificial
light may affect the dusk switch or where flashes or reflections may be produced.
Open the device by removing the two fixture screws situated in the base.
Insert 2 rubber tubes in the opening at the base of the device.
Pass the wires through the tubes and connect them to the connection terminals as
shown in the diagrams.
Insert the connection strip in the pylons at the base of the device and fasten the
wires by means of the provided wire holder with two screws.
Close the device by making sure the two existing marks at the top and the base
coincide and fasten it with the two screws.
ENG
VEGA
TWILIGHT SWITCH
ADJUSTMENT
The adjustment of the dawn switch must be carried out when the surrounding light
is that required to switch on the lighting, operating on the adjustment
potentiometer.
Turn it anti-clockwise to minimum. Then turn it gradually in the opposite direction
until the LED lights up. The light will switch on approximately 60 seconds after the
LED lights up.
The dawn switch turns on and switches off after an approximate delay time of 60
seconds. The purpose of these delay mechanisms is to avoid them being activated
or switched off due to sudden changes in the light (lightning, clouds, headlights,
etc.)
TECHNICAL CHARACTERISTICS
Supply
Breaking power
Maximum Recommended charges
Incandescent lamps
Fluorescent tubes
Low voltage halogen (12 Vac)
Halogen (230 Vac)
Low consumption lamps (CFL)
Low consumption lamps (Downlights)
Led lamps
Own consumption
Sensor type
Sensibility
Lighting up delay
Switching off delay
Working temperature
Degree of protection
Class of protection
DIMENSIONS
04/02.2016
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
230V~ 50Hz
10(3) A / 250V~
2000 W
100 VA
1000 VA
1000 W
100 VA
100 VA
50 VA
8VA (1W approx.)
Sulphur Cadmium
5-300 Lux. Logarithmic.
60 seconds
60 seconds
-30 C to +50 C
IP 54 according to EN 60529
II according to EN 60335 with
correct installation
A016.13.50527
E–28020 MADRID
Fax:+34 91 5714006
E-mail:
info@orbis.es
http://www.orbis.es