Volumetric Flow Monitoring; Working; Autoclean - Cleaning The Main Filter (Only Versions With Autoclean) - Festool CTM 26 E Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
English
Make sure that the contacts [10-2] are
free.
► Replace the top section [2-1] and close the
locking clips [2-2].
7.9

Volumetric flow monitoring

An acoustic warning signal sounds if the air
speed in the suction hose falls below 20 m/s (at
dust class 'M',).
The table on the mobile dust extractor ex­
plains this connection for the minimum re­
quired extraction volume of the respective
hose diameter. If the rate is below the re­
spective extraction volume, a warning sig­
nal is emitted.
Possible causes
Value set on the suction power adjust­
er [1-10] is too low.
Rotary knob [1-9] not set to the correct
hose diameter.
Suction hose blocked or kinked.
Filter bag full.
Filter element clogged.
Monitoring electronics malfunction.
Wet extraction.
8

Working

8.1
Handling
Hose holder: After finishing work, you can feed
the suction hose through the opening [8-2] and
place it in the hose holder.
SysDoc Systainer storage area: A Systainer can
be fastened to the storage area with the four
slides or the T-Loc lock [8-1].
8.2
AUTOClean - Cleaning the main filter
(only versions with AutoClean)
Only in conjunction with disposal bag
(compliance with dust class 'M'). Not
suitable for wet extraction!
Automatic cleaning
Adjust the frequency using the rotary
knob [1-8].
Only CTM 36 E AC-LHS / CTM 36 E AC-
RENOFIX: switch on using the rotary
knob [1-8].
20
* only for EU versions of CT AC
Solution
Set the suction power adjuster to a higher value (see
Chapter 7.4).
Set the knob to the correct hose diameter (see Chap­
ter 7.1 ).
Remove blockage or kink.
Insert a new filter bag (see Chapter 7.7 ).
Change the filter element (see Chapter 9.1).
Only AUTO Clean : clean filter element (see chap­
ter 8.2).
Send to a Festool service workshop for repair.
Functional reliability not affected, no actions required.
Manual cleaning
Turn the switch [1-11] to the AC symbol.
Full manual cleaning
► Cover the end of the nozzle or suction hose
with your hand or closing slide CT-VS
(497926) for 2 seconds.
► Turn the switch [1-11] to the AC symbol.
8.3
Special features of the CTM 36 E AC-
LHS
To use the mobile dust extractor in combination
with the PLANEX:
► Use kink-resistant suction hose D 36 mm x
3.5 m-AS.
► Use a special suction sleeve for connecting
the PLANEX.
► Use closing slide CT-VS between the intake
opening [1-2] and suction hose.
► Attach the tool holder.
► Always use with a disposal bag!

Publicidad

Tabla de contenido
loading

Tabla de contenido