1ST PHASE (Adjustments and checks)
1 - Release the motors
2 - Put the leaves into the intermediate position and then lock the motors. Move the leaves slightly by hand so the
gears engage.
3 - Set the microswitches DIP 1-2-3-4-5-6-7-12-14-16-17 in OFF position and the microswitches DIP 13-15-
18-19-20 in ON position (in case of an electric lock put microswitches DIP 8-9-10-11 in ON position too)
4 - Put DIP 1 on ON. The DL1 LED flashes.
5 - Press the PROG button and hold it. The DL2 and DL4 LEDs turn on. M1 must open followed by M2 while PROG
is pressed.
After 3 seconds and up to 10 seconds turn the TORQUE trimmer clockwise to increase force (if
necessary).
After 10 seconds Low speed starts. Adjust it via the LOW SPEED trimmer.
6 - Release the PROG button. If necessary, reverse V with W of the motor(s) that close to re-establish
correct movement direction.
7 - Press the PROG button and hold it. The DL5 and DL3 LEDs turn on. M2 must close followed by M1. Keep PROG
pressed until the gate has closed completely.
8 - Put DIP1 on OFF. The DL1 LED stops flashing
2nd PHASE (Programming total opening time)
ATTENTION: DURING PROGRAMMING THE SAFETY DEVICES ARE ACTIVE AND THEIR INTERVENTION STOPS PROGRAMMING
(THE DL1 LED FROM FLASHING REMAINS ON FIXED). TO REPEAT THE PROGRAMMING PROCEDURE POSITION
THE DIP 1 AND DIP 2 TO OFF, CLOSE THE GATE THROUGH PROCEDURE
THE PROGRAMMING OF THE CHOICE.
1 - The gate must be completely closed.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG./RADIO/OPEN/START button => M1 opens.
4 - When M1 has reached the mechanical opening stopper => after 1 second press the PROG./RADIO/OPEN/START button to stop M1
and open M2.
5 - When M2 has reached the mechanical opening stopper=> after 1 second press the PROG./RADIO/OPEN/START button => M2 stops.
6 - Press the PROG./RADIO/OPEN/START button => M2 closes.
7 - After a few seconds press the PROG./RADIO/OPEN/START button => M1 closes and determine the phase displacement between M2
and M1.
At the same time the LED DL1 will stop flashing, signaling the exit from the programming procedure.
From this moment the safety devices or other gate commands will work normally (inversions, stops, alarms, etc.).
8 - When the time is over, the gate stops.
9 - AT THE END OF PROGRAMMING, RESET THE DIP 2 IN OFF POSITION.
3rd PHASE Programming the remote control
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
2 - Press the remote button (usually channel A) within the allotted 10 seconds. If the remote is memorized
properly LED DL12 blinks green and a buzzer tone confirms the correct memorization. The 10 seconds
for programming the codes are automatically renewed, with LED DL12 which flashes red, in order to
store the next transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12 stops flashing.
ON
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
4th PHASE (Programming pedestrian opening times)
The gate must be fully closed.
1 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly.
3 - Press the pedestrian pushbutton (COM A+/PED.), motor M1 opens
4 - When the motor M1 leaf is opened enough for the pedestrian crossing, press the pedestrian
pushbutton to stop the travel (thus defining the opening stroke of motor M1).
5 - Press the pedestrian pushbutton (COM A+/PED.), M1 closes.
6 - Turn DIP1 and DIP 2 to OFF position.
5th PHASE Customising the configuration
The configuration can be modified by moving the various microswitches
DIP 4
DIP 5
DIP 6
DIP 7
ON
DIP 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DIP 9
DIP 10
DIP 11
DIP 12
DIP 13
DIP 14
DIP 15
AND REPEAT
Adjustments and checks
DIP 16
DIP 17
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DIP 18-19-20 must remain ON for IDRO C 27/1B
ATTENTION: Install the APP card (or the APP+ card with its modules) and use your smartphone with the RIB GATE App to take
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Photocells always active (OFF) - Photocells active only during closing (ON)
Pre-blinking (ON) - Normal blinking (OFF)
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
Photocells AUTO-TEST activation (ON-activated).
Electric lock activation (ON-activated)
Electric lock pulse release (ON-activated)
Motors manual release facilitation (ON-activated)
Electric lock pulse engagement (ON-activated)
Selection of 1 or 2 motor operation (default OFF 2 motors)
Activate the radio system SUN/MOON (ON) - SUN-PRO (OFF)
Timed operation (OFF) - Operation with limit switches (ON)
Slowdown (ON - activated)
Contactors management (ON - activated)
Encoder management (ON - activated)
advantage of all the advanced features that the B2 control board can offer you.
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20