ISEO Zero1 Atlas Plus Guia De Instalacion página 4

Ocultar thumbs Ver también para Zero1 Atlas Plus:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

V364 F9000 SYSTEM WIRING:
4.
2 DOORS CONTROLLER CONNECTION EXAMPLE
Maximum number of devices
that can be connected to the
RS485 channel = 1 (per
channel).
Devices consumption:
- ATLAS = 10 W
- F9000 reader= 1W
- Actuator = 3W
Wirings also applies to Atlas
Standard
DOOR 2
(F9000 reader
cod.E032**)
WIRING SPECIFICATION
Use an Ethernet cable FTP AWG24 CAT5E (and above).
Maximum Ethernet cable length between Atlas and F9000 Reder: 500mt.
Connect a resistance value of 120 ohm (1/4W), on both Atlas and F9000
Reader sides, as shown in the scheme.
Conductor capacitance < 100pF/m.
Conductors electrical resistance max 90 ohm/Km.
J6
J11
DOOR 1
(F9000 Reader
cod.E032**)
Schield
SER.A/B
SER.A/B
+ V Power
GND
J7
J5
J4
J14
Power supply unit:
24 VDC - 1,65 A
(35 W)
BACK SIDE
J17
S3
S1
12 VAC
L R L
P1
L 1
L 2
P2
ELECTRIC LOCK ACTUATOR
DOOR 1
Cod. 5E2501**
Power supply
(Actuator cod.5E2501)
8÷ 30VDC 0.5A
LVO
JP 1
LC H
JP 2
L P W
JP 3
12 VAC
P1
L 1
L 2
P2
L R L
ELECTRIC LOCK ACTUATOR
DOOR 2
Cod. 5E2501**
Power supply
(Actuator cod.5E2501)
8÷ 30VDC 0.5A
LVO
JP 1
LC H
JP 2
L P W
JP 3
DOOR 1
DOOR 2

Publicidad

Tabla de contenido
loading

Productos relacionados para ISEO Zero1 Atlas Plus

Tabla de contenido