Wear parts
Impeller (20) and foam filters (7) are wearing parts and are, therefore, not covered by our warranty.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Clean the unit thoroughly, check for damage and
store immersed in a frost-free environment. Ensure that the power plug is not flooded.
Remedy of faults
Malfunction
The unit does not switch on
Insufficient delivery rate
No aeration
Unit switches off after a brief running time (ap-
prox. 10 s)
The unit floats up
Unit floats up, pump is switched on
Disposal
Dispose of the unit in accordance with the national legal regulations.
Cause
No mains voltage
Air in the pump housing
Impeller blocked
Filter basket soiled
Air hose kinked or disconnected
The air hose is not inserted up to the mark in
the intake socket
Water temperature too high
Pump run dry
Filter basket full or clogged
Impeller soiled
Remedy
Check mains voltage
Pull the power plug; for venting, tilt the unit to-
wards the skimmer flap
Clean
Clean
Ensure secure fastening and avoid kinks in the
air hose
Correctly position the air hose in the intake
socket
Note maximum water temperature of +35°
Clean pump and unit For switching on again,
pull the power plug and reinsert in the socket
Switch off the unit and clean filter basket
Switch off the unit and clean impeller
- EN -
11