- GB -
Aquamax Eco Classic 2500
• In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
Clean pump
How to proceed:
10.
0.
G
1. Screw off the stepped hose adapter.
2. Remove screws.
− The screws are used as transport protection and not required for operation.
3. Actuate the engagement hook and fold up the strainer top casing.
4. Remove pump.
5. Unscrew the pump housing and pull out the impeller unit.
− Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
− Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
Aquamax Eco Classic 3500/5500/8500/11500/14500/17500
• In the event of the filter housing capacity reducing, clean the unit under running water using a brush.
Clean pump
7.
How to proceed:
0.
H
1. Screw off the stepped hose adapter.
2. Remove screws.
− The screws are used as transport protection and not required for operation.
3. Actuate the engagement hook and fold up the strainer top casing.
4. Remove pump.
5. Remove screws.
6. Remove the pump housing including its holding ring, sealing and impeller unit.
− Clean all components under running water using a soft brush, replace damage parts.
7. Reassemble the unit in the reverse order.
− Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
Wear parts
The impeller unit is a wearing part and does not fall under the warranty.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
14