Descargar Imprimir esta página

Menu Selection - Kübler CODIX 555 Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

5 5 . . 2 2 . . 3 3 C C h h a a n n g g i i n n g g t t h h e e R R a a n n g g e e L L i i m m i i t t s s
The given limits for the input range can be
entered as is, or adjusted.
Parameter
Possible range of values
0 .. 10 V
–0.500 ... 10.500
2 .. 10 V
01.500 ... 10.500
-10 .. +10 V –10.500 ... 10.500
0 .. 20 mA
–1.000 ... 21.000
4 .. 20 mA
03.000 ... 21.000
If the measured signal falls below or ex-
ceeds the programmed value, then the
display alternates between
the measured value or between
and the the measured value.
L L o o w w e e r r l l i i m m i i t t
Menu <–> Selection
press the
key to accept the selection
U U p p p p e e r r l l i i m m i i t t
Menu <–> Selection
press the
key to accept the selection
Page 12
Parameter
Possible range of values
–0.500 ... 10.500
01.500 ... 10.500
–10.500 ... 10.500
–1.000 ... 21.000
03.000 ... 21.000
and
Example: –5.000
Select digit
Set digit
Select digit
Set digit
Example: 9,000
Select digit
Set digit
Setting values out of the range is not pos-
sible. It is only possible to continue with
the set-up, using the
settings are correct.
When the signal drops below the value
set here, then the signal alternates with
the message
U U n n d d e e r r - - r r a a n n g g e e : : if the signal is less then
–13,60 V than
display.
Current values < 0.0 mA will not be
measured.
When the signal exceeds the value set
here, then the signal alternates with the
message
O O v v e e r r - - r r a a n n g g e e if the signal is higher than
11.00 V or 21.5 mA, then
appears in the display..
key, when the
appears in the
www.kuebler.com

Publicidad

loading