GENERAL DESCRIPTION
TAG READER is a proximity reader with data output in Wiegand or Dataclock format. TAG READER works with the proximity badges and tags.
All the electronic components and the antenna are assembled in an entirely sealed container with high resistance to atmospheric agents (IP67).
The TAG READER reader is equipped with a two-colour red/green LED and a buzzer to indicate the various functioning phases.
To install, assemble the reader and connect the cable to the access control unit in accordance with the instructions shown below.
2.
TECHNICAL FEATURES
Power supply
Average absorption
Reading technology
Reading range
Signalling
Connection distance to the host
Insulation class
3.
C ON NECT IO NS
RED
GRAY or BLACK
GREEN
WHITE
ORANGE
CYAN or BLUE
YELLOW
BROWN
VIOLET
PINK
4.
F UN CT IO NI NG
Power up the reader. The buzzer beeps once and the led turns on (red).
Place a badge or a tag in front of the reader: the buzzer sounds, the LED turns into green and the code of the badge is output at DATA0-DATA1 in
Wiegand 30 bit format. The LED remains green and the PRESENCE line (PINK wire) goes low (0V) as long as the badge is hold in the field of the reader.
The standby status of the PRESENCE line is high (5V)
5.
D AT A FO RMAT
If the MODE input (BROWN wire) is left unconnected or tied to 5VDC the output data format is Wiegand. If the MODE input is connected to GROUND the
output data format is DataClock.
While in Wiegand mode (BROWN wire unconnected or tied to 5VDC), if the WIEGAND FORMAT input (YELLOW wire) is left unconnected or tied to
5VDC, the data format at DATA0-DATA1 is 30-bit Wiegand. If the WFMT input is connected to GROUND, the data format at DATA0-DATA1 is 26-bit
Wiegand.
6.
LED DRIVING
If the ORANGE and CYAN wires are left unconnected or tied to 5VDC the status of the led is driven by the reader itself. If
one or both of the ORANGE and CYAN wires are connected to GROUND, the status of the LED changes as follows:
ORANGE wire
GROUND
GROUND
5VDC or floating
7.
ASSEMBLY INSTRUCTIONS
To assemble the reader, drill two 2.5 mm. holes in the support bracket for the fixing screws and one 6 mm diameter hole for the cable (fig. 1). Place an
insulating gasket around the hole. Hook-up the interface cable from the reader to the access control station and mount the reader using screws with a max.
diameter of 3 mm (fig. 2).
Fix the cover to the base, pressing until the hooks click into place (fig. 3).
Connect the reader to the host following the instructions in the table below and in the central unit installation manual. The table shows the connections
for the TAG999 unit.
Keep in mind that installing the reader on metal surfaces could decrease the reading distance.
TAG READER
RED
+12 Vdc
BLACK
GROUND
GREEN
DATA 0
WHITE
DATA 1
DECLARATION OF CONFORMITY
The equipment READER TAG READER IS IN ACCORDANCE with the 99/05/EC (R&TTE) directive.
12 VDC
20 mA
Proximity - 125 KHz
8 cm
Bicolour led (red/green), buzzer
100 meters max.
IP 67
12 VDC
GROUND
DATA0
DATA1
Red LED driving
Green led driving
WIEGAND FORMAT
MODE
Not used
PRESENCE
CYAN wire
LED status
GROUND
OFF
5VDC or floating
RED
GROUND
GREEN
TAG999