Hitachi DV 14DMR Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Battery
Pilot Lamp
Fig. 5
2. Insert the battery to the battery charger
Insert the battery into the battery charger as shown in Fig. 5. Make sure it contacts the
bottom of the battery charger.
3. Charging
When the battery is connected to the battery charger, charging will commence and the
pilot lamp will light in red. (See Table 2)
NOTE: If the pilot lamp flickers in red, pull out the plug from the receptacle and check if
the battery is properly mounted.
When the battery is fully charged, the pilot lamp will blink in red slowly. (At 1-second
intervals) (See Table 2)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in Table 2, according to the condition
of the charger or the rechargeable battery.
Before
Blinks
charging
(RED)
While
Lights
charging
(RED)
Charging
Blinks
complete
(RED)
Charging
Flickers
impossible
(RED)
Charging
Lights
impossible
(GREEN)
<UC14YFA>
1. Insert the plug of battery charger into the receptacle
When the plug of battery charger has been inserted into
the receptacle, pilot lamp will blink in red. (At 1-second
intervals)
Table 2
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Lights continuously
WARNING:
Do not use the electrical cord if
damaged.
Have
immediately.
Malfunction in the battery or
the charger
The battery temperature is high,
making recharging impossible.
English
it
repaired
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dv 18dmr

Tabla de contenido