English
CleanSpace Respirators
CLEANING THE HARNESS AND NECK SUPPORTS
The harness and neck supports can be washed in warm soapy water or machine washed. After cleaning, allow the harness and
neck supports to air dry in a clean environment. Do not dry by exposing directly to heat i.e. hair dryers or heaters
15. Recalibration
You must recalibrate the internal pressure sensor any time that your CleanSpace Respirator is exposed to changes in
1.
With CleanSpace Respirator in Standby mode (one or more green LEDs lit), press and hold both the Power button and the
Filter Test button.
2.
When both the blue and red LEDs light, release both buttons.
3.
Hold the CleanSpace Respirator still until the red and blue LEDs turn off (10 – 15 seconds)
4.
The calibration is complete
16. Approvals
CleanSpace Respirator is a complete respiratory protection system. In addition some combinations of components have
been approved for use in some explosive atmospheres. Not all of the components shown in this manual have been approved
SEE NEXT PAGE FOR A LIST OF THOSE COMPONENTS THAT HAVE IECEx / ATEX APPROVAL
RESPIRATORY PROTECTION APPROVALS (ALL CLEANSPACE RESPIRATORS & ACCESSORIES)
EN 12942: 1998 + A2:2008
TM3
WATERPROOF APPROVAL (CLEANSPACE ULTRA AND SEE TABLE BELOW)
IP RATING 66
EXPLOSIVE ATMOSPHERES APPROVALS (CLEANSPACE EX AND SEE TABLE BELOW)
IEC60079.0:2012,
IEC60079.11:2011
Ex ia I Ma,
Ex ib IIB T4 Gb
EN 60079-0:2012, EN 60079-
11:2012
I M1 Ex ia I Ma
II 2 G Ex ib IIB T4 Gb
temperature of more than 20°C.
If no LEDs are lit, press the Power button once to enter Standby mode.
for use in explosive atmospheres.
Key to IECEx markings:
Ex
Explosion protected
ia
Type of ignition protection (intrinsic safety, very high protection)
ib
Type of ignition protection (intrinsic safety, high protection)
I
Gas Group (Methane)
IIB
Gas group Ethylene
Ma
Equipment protection level for underground mining (very high)
T4
Temperature class (Maximum surface temperature 135C
Gb
Equipment protection class (high)
Key to ATEX markings:
Explosive area symbol
I
Equipment Group (underground mines)
II
Equipment Group (explosive atmospheres other than underground mines)
2G Equipment category (2 = High level of protection, zone 1. G = gas)
Ex
Explosion protected
ia
Type of ignition protection (intrinsic safety, very high protection)
ib
Type of ignition protection (intrinsic safety, high protection)
IIB Explosion group Ethylene
T4 Temperature class (Maximum surface temperature 135C
Gb Equipment protection class (high)
AS/NZS 1716:2012
PAPR-P2 (with half face masks)
PAPR-P3 (with full face masks)
28
USER INSTRUCTIONS