Description (fig. A)
Your DC390 cordless circular saw has been
designed for professional sawing applications.
1 On/off switch
2 Lock-off button
3 Front handle
4 Spindle lock
5 Dust spout
6 Saw shoe
7 Riving knife
8 Lower guard retracting lever
9 Lower guard
10 Saw blade
11 Bevel adjustment knob
12 Kerf indicator
13 Depth adjustment knob
14 Battery pack
Charger
Your charger DE9116 accepts D
battery packs ranging from 7.2 to 18 V.
14 Battery pack
15 Release buttons
16 Charger
17 Charging indicator (red)
Electrical safety
The electric motor has been designed for one
voltage only. Always check that the battery pack
voltage corresponds to the voltage on the rating
plate. Also make sure that the voltage of your
charger corresponds to that of your mains.
Your D
WALT charger is double
E
insulated in accordance with EN 60335.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
WALT NiCd/NiMH
E
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.
Never use a light socket.
Never connect the live (L) or neutral (N)
wires to the earth pin marked E or
Using an extension cable
An extension cord should not be used unless
absolutely necessary. Use an approved extension
cable suitable for the power input of your charger
(see technical data). The minimum conductor size is
2
1 mm
; the maximum length is 30 m.
Assembly and adjustment
• Prior to assembly and adjustment,
always remove the battery pack.
• Always switch off the tool before
inserting or removing the battery pack.
Use only D
chargers.
Battery pack (fig. A & B)
Charging the battery pack
When charging the battery pack for the first time, or
after prolonged storage, it will only accept an 80%
charge. After several charge and discharge cycles,
the battery pack will attain full capacity.
Always check the mains prior to charging the battery
pack.
E N G L I S H
WALT battery packs and
E
.
27