Signal transmission/processing characteristics
Handshake :
Insulation :
Speed :
Configuration :
Other functions available :
General Technical Features
Insulation voltage :
Protection :
Environmental conditions :
Storage temperature:
Dissipation:
Signalling by LED :
Connections :
Wire section :
Wire stripping :
Box :
Dimensions and weight :
Reference standards :
Timed automatic
Optical
1200...115200 bps
by dip-switch
X or Y side terminator, X->Y or Y->X communication
direction inhibition
1.5 kV between each pair of ports
IP20
Temperature: -20 ... +65°C
Humidity: 10 ... 90% non-condensing
Altitude: up to 2000 m. a. s. l.
-40..+85 °C
Lower than 500 mW
Data Presence on X port, Data presence on Y port,
inverted connection on X port and inverted connection
on Y port.
Cable clamp terminals and bus (rear connector for DIN
and K-BUS bar)
2
0,2..2,5 mm
8 mm
PBT, black
6,2 x 93,1 x 102,5 mm, 46 g.
EN61000-6-4/2002 (electromagnetic emission, industrial
environment) EN61000-6-2/2005 (electromagnetic immunity,
industrial environment)
All circuits must be insulated from the other circuits under
dangerous voltage with double insulation. The power supply
transformer must comply with EN60742: "Insulated
transformers and safety transformers".
Notes: - Use with copper conductor.
- Use in Pollution Degree 2 Environment .
- Power Supply must be Class 2.
- When supplied by an Isolated Limited Voltage/Limited
Current power supply a fuse rated max 2.5 A shall be
installed in the field.
EN61010-1/2001 (safety).