Beta 599DGT-A/10 Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
PEAK HOLD MODE OPERATION
((...((...
((((((((
Note:
1. If
2. If
Please refer to the section "Reading in peak hold mode values" to clear old records.
3. When 80% of the target torque value is reached, the green LED will start blinking, and an intermittent
sound will be heard.
4. When 99.5% of the target torque value is reached, a continuous sound will be heard, and the green LED
will stop blinking and will remain on. The red LED will also turn on.
20
Start
(System initialization)
* Note 1
Set torque value
Applying torque
Released
Apply torque
Current torque
value
(Peak Hold)
Reaching 80% of target torque
...))...)) ((...((...
Buzzer
Reaching target torque
))))))))
Buzzer
appears, that means more than 110% of maximum torque has been reached.
appears, that means the memory of the wrench is full, and no other value can be recorded.
* Note 2
Record
Flashing
* Note 3
...)) ...))
Green LED
80% of target torque reached
* Nota 4
(((((((
)))))))
Red LED
Target torque reached

Publicidad

Tabla de contenido
loading