Mounting
Expansion wall plugs are provided to secure the hood to
most types of walls/ceilings. However, a qualified technician
must verify suitability of the materials in accordance with the
type of wall/ceiling. The wall/ceiling must be strong enough to
take the weight of the hood. Do not tile, grout or silicone
this appliance to the wall. Surface mounting only.
Description of the hood
Fig. 1
H. Interconnection cable
K. Control lever
Attention! The control lever is already supplied. It is to
be installed last, before connecting the hood to the
mains.
Insert the control lever into the apposite housing (see
drawings on the first pages of this booklet - triggered
connection, compulsory direction.
L.
Halogen bulb
M. Lateral filter holder frame
N. Active carbon filter
O. Metal anti-fat filter
P. Anti-fat and carbon filters holder frame
Q. Filter holder frame releases
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
The hood is equipped with a "TOUCH" device to control the
lights and speed.
For the correct use please carefully read the intructions below.
The cooker hood can be controlled through a remote control
available as accessory kit (see the paragraph relating to the
functioning of the remote control).
Automatic start-up function
The hood is equipped with a temperature sensor which
activates the motor to the first suction speed (power) in the
event that the room temperature in the surrounding area is
higher than 70°C.
The user may switch off or modify the suction speed (power)
(see paragraph "suction speed (power) control").
Suction speed (power) control
The suction speed (power) is cyclical depending on the speed
sequence "stand-by – 1-2-3-4- Stand by -1-2-..." therefore
every time the T1 button is pressed on the control panel, the
suction speed (power) is increased by one level, in order to
switch off (stand-by) if the button is pressed again when the
hood is in suction speed (power) 4.
The hood may be switched off (stand-by) while the hood is set
on any speed by holding down the T1 button on the control
panel for a bit longer (more than 3 seconds).
The hood's suction speed (power) may be determined as the
control panel is equipped with a LED light that changes colors
as follows, depending on the suction speed (power):
Hood in stand-by: LED LIGHT SWITCHED OFF
1 st suction speed (power) -GREEN LED LIGHT
2 nd suction speed (power) – ORANGE LED LIGHT (amber)
3 rd suction speed (power) - RED LED LIGHT
4 th suction speed (power) - RED LED LIGHT (FLASHING)
Note: The 4 th suction speed (power) stays on for 5 minutes,
after which the suction motor will position itself on the 2 nd
speed.
If pressed again, the suction motor will switch off (stand-by).
Grease filters need cleaning: FLASHING GREEN LED light
(read instructions found under "Reset and configuration for
filter saturation signal")
Coal filters must be cleaned or replaced: FLASHING
ORANGE (amber) LED light (read instructions found under
"Reset and configuration for filter saturation signal")
Note: The reset procedure may be activated by both the
control panel and the remote control.
Center light check
The center light may be switched on and off by pressing the
T2 button on the control panel.
Side light check (when scheduled)
The side lights may be switched on and off by pressing AND
HOLDING DOWN the T2 button on the control panel.
HOLDING DOWN the button, besides permitting to switch the
hood on and off, it also regulates the light intensity given from
the lights.
Note: The switching on and off functions (and regulating
function) alternate.
The regulation of the light intensity is not available for hoods
with neon lights.
15