ELEGANCE
The two-part shower door is made for a wide area, such as over an oblong bathtub or for a built-in shower tray.
The doors are produced in sizes 110 and 120cm, marked
The shower doors come as a complete set including a mounting kit.
ATTENTION!
You will find the mounting kit inside the carton.
To mount this product into a finished bathroom, it is important to carefully and thoroughly measure and fix both
parts of the shower enclosure to the wall. You must also adjust the doors to their correct position and test their
function, assemble the door handles, drip sills and other components. We reco mmend the assembly and
installation be done by a trained specialist from either our company, or from another installation firm.
FOR THIS PRODUCT TO FUNCTION PROPERLY IT SHOULD
ONLY BE INSTALLED ON STRONG WALLS.

MOUNTING PROCEDURE

1.
Check the size of the recessed area for fit. Width "A" (
ding to the chart. The shower tray must be mounted level.
2.
Check the position and layout of the doors. In the upper part of the
doors there are slots cut into the corners of the glass. The upper part of
the plastic post has an opening of 10 mm in diameter for the decorative
cap.
3.
Place one of the doors on the built-in shower tray (
the edge of the plastic post is 5 - 20 mm from the outer top edge of the
tray, and so that the plastic post completely sits on the rim of the shower
tray. Mark the position on the wall.
4.
Using your fingers, gently press the edge of the plastic moulding.
Loosen and remove it from the mounting profile (
5.
Unscrew the three M5 screws with washers and remove the mounting
profile from the winged door (
detailed in picture 4
profile into the marked position on the tray, then stand it up vertically and
mark the oval opening of the mounting profile on the wall (
ATTENTION!
If the shower tray is not level, it is important that the super-
structure be placed perpendicular to the tray, and from this position it can
be fastened to the wall.
6.
Set aside the mounting profile. In the center of the marked oval, drill
a 10 mm diameter hole and place a dowel in it (
ATTENTION!
Watch out for electrical cables and water and gas mains in
the wall!
7.
Fix the mounting profile to the wall using 5 x 50 mm bolts. Only lightly
tighten the bolts (
picture 8
).
8.
Mark and attach the other mounting profile in the same way.
9.
Attach the door to the mounting profile using M5 screws and washers.
Mount the other door in the same way.
10.
Use the slots and screws on the mounting profile to adjust the doors:
- on the edge of the tray, where the doors touch each other, use a shim
(piece of wood) 18-20 mm in thickness to rest the doors on;
- the doors must follow the shape of the shower tray;
- the doors must touch along their entire length so that the magnets can
hold them in the right position;
- the height of both doors must be the same, and the lower edge of the
glass must be level to the shower tray.
11.
After doing all of the adjustments, tighten the four visible bolts and the
three M5 screws on each mounting profile. Remove the shim and test the
function of the doors. Check the distance from the lower edge of
the glass to the shower tray with the enclosed gauge (the 16.5 x 20 mm

CLEANING AND MAINTENANCE

ATTENTION!
Only use a soft cloth and normal household detergent for cleaning the lacquered surfaces, glass and plastic panels. Avoid using abrasive pastes, solvents,
acetones,chlor, etc.
We reco mmend the line of
RAVAK ANTICALC
qualities of the
RAVAK ANTICALC
acrylic bathtubs, washbasins and water taps;
manufacturer is not responsible for damage caused by misuse, improper installation and repair of the product. The manufacturer has the right to constant
innovation and changes of the product.
The guarantee of the product is 24 months, only if the installation has been done by an authorized firm holding a certificate for Ravak products. In all other
cases, the guarantee time limit will be determined in accordance with the appropriate legal terms.
For further information concerning assembly, installation, and use and maintenance, please contact your local dealer.
Two-part shower enclosure
ESD2-110
picture 2
) accor-
picture 3
), so that
picture 4
).
). Place the mounting
picture 5
picture 6
).
products:
RAVAK ANTICALC CONDITIONER
coating;
RAVAK CLEANER
worpcs to remove old and dried-on debris from glass surfaces, shower frames, enamel and
RAVAK DISINFECTANT
RAVAK a.s.,
Obecnická 285, 261 01 Pøíbram I
tel.: +420 318 427 111 fax: +420 318 427 269
e-mail: smith@ravak.cz, www.ravak.com
and
ESD2-120.
roller). When the doors are in the closed position, the clearance between the
bottom edge of the glass and the shower tray should be between 16.5 mm and
20 mm.
12.
On the mounting profile, outline the exact position of the adjusted doors.
From one door, unscrew the M5 screw which is holding it in place. Remove the
door and tighten the bolts inside the mounting profile. Place some sealing
compound on the bottom of the plastic door post (for mounting to the shower
tray). Place the plastic joint of the threshold strip into the slot in the plastic post,
with the higher side to the outside of the shower tray (
doors back into the marked position and tighten the M5 screws. Follow the
same procedure for the other shower door.
13.
Test the function of the doors several times and check the lifting mechanism.
14.
Drill holes of 2.6 mm in diameter in the frame of the doors according to the
pre-drilled holes in the mounting profile. Secure the frame using 3.5x13 mm
self-tapping screws.
).
15.
Place one side of the plastic moulding into the mounting profile and push
slightly along the whole length to "lock" it into place (
16.
Test, and if necessary, adjust the shape and length of the threshold strip so
that the whole length of the bottom of the strip is in contact with the shower
tray.
17.
Place the threshold strip into the plastic joints on both door posts.
18.
Bead the threshold strip with a small amount of quick glue along its entire
length (approximately 200 mm), and point by point, glue it to the tray.
19.
Place a small amount of sealing compound into the slots for the threshold
strip and completely seal it to the tray (
20.
To complete the seal, put sealing compound on the seams between the
wall and the mounting profiles, and along the outer side of the supporting
posts to a height of 100 mm above the tray (
All joints and seals should be done with
compound which ensures a perfect cohesion of the plastics used.
21.
Fit the drip sill onto the bottom of the glass doors and test the function of
the doors. Adjust the drip sill if necessary.
22.
Remove the drip sill and put quick glue on the entire surface of the cut end
and along the entire inner groove. Re-mount the sill and push it into the origi-
nal position. Glue the ends to the posts and seal all the seams of the drip sill
with sealing compound on the bottom and sides and on the post.
23.
Put some silicon on the underside of the decorative cap and seat it on the
upper end of the plastic post (
24.
Assemble the handles according to the instructions given with the product.
is a special preparation with notable anti-bacterial and anti-fungal effects. The
ESD2 110, 120
CONTENTS OF MOUNTING KIT
1. Decorative cap
2. Plastic drip sill R + L
3.
Plastic joint for threshold strip R + L
4. Dowel 10 mm diameter
5. Dowel bolts 5x50 mm diameter
6. Self-tapping screws 3.5x13 mm
7. RAVAK sealing compound
8. Threshold strip
9. Quick glue 2 grams
10. Drill bit 2.6 mm diameter
11. Mounting instructions
12. Gauge 16 mm diameter
13. Washer 5 mm diameter
picture 10
picture 11
RAVAK PROFESSIONAL
picture 14
).
a preparation which perfectly renews and maintains all the
2pcs
1+1pc
1+1pc
12pcs
12pcs
8pcs
1pc
1pc
1pc
1pc
1pc
1pc
12pcs
picture 7
). Place the
picture 9
).
).
).
sealing
MN ESD2 - 2/2003

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Esd2 120

Tabla de contenido