Incidents And Solutions Table; Incidents And Operation Table - Fermax 6030 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Kit VIDEO DIGITAL
Kit VIDEO DIGITAL

INCIDENTS AND SOLUTIONS TABLE

SYMPTOM
• Does not enter programming mode.
• Auto-on does not work.
• I does not enter programming
mode.
• Auto-on works.
• There is no call, but there is panel
call monitoring.
• When call button is pressed, the
Diagnostic LED does NOT ligth
at all.
• There is no call, but there is panel
monitoring.
• When call button is pressed, el
Diagnostic LED emits short
flashes.
• The panel emits a continuous se-
ries of short beeps.
• Very weak audio sound, or fee-
dback that cannot be eliminated
with
the
audio
potentiometers.
• The door lock release/electric lock
is not working properly.
Pag 34
- Negative wire cross-section. Increase.
- Distance between panel and monitor. Increase cross-section
or add additional power supplies.
- Power source position. Maximum distance to panel: 30 metres.
Increase section or add additional power supply.
- Resistor 10 KOhms.
- Distance between panel and monitor. Increase cross-
section or add additional power supplies.
- Check that Jumper JP1 is set in the panel.
- Check that the monitor is switched on.
- Check cable «L».
- Monitor programmed wrongly. Program it again.
- Short circuit between «L» and «+».
- Short circuit between «L» and «-».
- Resistor 10 KOhms. There must be only 1 resistor in
the furthest monitor.
adjustment
- Make sure you are using a 12 Vdc door lock release
(direct current), 0.3 A. máx.
- Increase negative cross-section.
- Distance between panel and monitor. Increase cross-
section or add additional power supplies.
- Power supply position. Maximum distance to panel: 30
metres. Increase croos-section or add additional power
supplies.
POINTS TO CHECK