Auto Off
45 min
LO M
Do not
overtighten
+
2 AA
screw
+
OFF
W
Warning
Disconnect test leads from power source
before opening battery door.
Débranchez les cordons d'essai avant
d'ouvrir le couvercle de la pile.
Prima di aprire lo sportello del vano della pila,
scollegare i cavetti dal circuito di
alimentazione.
Die Prüfleiter vor dem Öffnen des
Batteriefachs von der Stromquelle trennen.
Desconecte los conductores de prueba de la
fuente de alimentación antes de abrir la
cubierta de la batería.
Antes de abrir a tampa do compartimento das
pilhas, desconecte os terminais de teste da
fonte de alimentação.
Maak de meetkabels los van de stroombron
voordat u de batterijklep opent.
Koble prøveledningene fra strømkilden før
batteridekselet åpnes.
Søgeledningerne skal tages evt. emne, inden
batteridækslet åbnes.
Irrota koestusjohtimet virtalähteestä ennen
paristolokeron avaamista.
Koppla bort mätsladdarna från strömkällan
innan du öppnar batteriluckan.
ELECTROSÓN
Specifications
Specifications subject to change without notice.
Calibration
1-year calibration cycle
Temperature
-10 °C to +50 °C (14 °F to 122 °F)
Operating:
-30 °C to +60 °C (-22 °F to +140 °F)
Storage:
Altitude
Operating:
2000 m (6562 ft)
Storage:
10,000 m (32808 ft)
0 % to 95 %, 5 ° C to 30 ° C
Relative
(41 ° F to 86 ° F); 0 % to 75 %,
Humidity
30 ° C to 40 ° C
(86 ° F to 104 ° F); 0 % to 45 %,
40 ° C to 50 ° C
(104 ° F to 122 ° F)
Battery Type
AA (2); 360 hours continuous with
and Life
alkaline; 125 hours continuous with
zinc chloride
RF Field
0.5 % full scale + (specified accuracy)
Specification
at 3 V / m
Enclosure
IP 52 per IEC 60529, no vacuum
Rating
applied
Safety
Complies with ANSI/ISA-S82.01-94,
UL classified to IEC 61010, CSA/CAN
C22.2 No.1010.1-92, and EN 61010-
1: 1995.
EMC
EN 61326
0.1 x (specified accuracy) / ° C for <18
Temperature
° C or >28 ° C (< 64.4 ° F or > 82.4 ° F)
coefficient
± ( [ % of reading] + [number of least
Accuracy
significant digits] )
Accuracy is specified for 1 year after
calibration, at 18 ° C to 28 ° C
(64 ° F to 82 ° F) with relative humidity
to 90 %. AC conversions are ac-
coupled, average responding, and
calibrated to the rms value of a sine
wave input.
CAT III protects against transients in a fixed equipment
installation such as a distribution panel, and lighting
systems in large buildings.
CAT IV protects against transients from a primary supply
such as an electricity meter or an overhead or
underground utility service.
Function
T5-600
T5-1000
Reso-
Accuracy
Range
Range
lution
K
± (1.5 % + 2
600 V
1000 V
1 V
rms
rms
digits)
L
± (1 % + 1 digit)
600 V
1000 V
1 V
?
± (3 % + 3 digits)
100.0 A
100.0 A
0.1 A
1000 V CAT III
600 V CAT IV
e
1000 Ω
1000 Ω
1 Ω
± (1 % + 2 digits)
P
$
Certifications:
In accordance with
IEC 61010-1, 54CJ
Replacement Parts
Test Lead Assembly.
PN 648029
Replace only with Fluke double-insulated
T
leads (
) See "Accessories" for available
probes.
Battery Door
PN 1626588
Battery Door Screw
PN 1618578

Publicidad

loading

Este manual también es adecuado para:

T5-1000