Deliming; Coupling - Nilfisk FOOD Yeti TW Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

This procedure should be
followed both on the detergent
and the disinfectant side (if this is
installed).

9.3. Deliming

• The interval of the Deliming procedure is depens
the water hardness.
• Make sure the water to the unit is disconnected.
• Remove the Cover from the unit.
• Dismount the injector block. Dismount the air
valve and the non-return valve for air, inclusive of
the air fittings.
• Put the injector block in a deliming bath.
• Wait for 60 minutes.
• Rinse the block in clean water.
• Mount the air valve and the non-return valve on
the injector block and mount the injector block in
the unit.
• Connect water to the unit.
• Test the unit make sure the vacuum is sufficient, it
is recommended to be between 14,8 - 20,7 in Hg /
-0.05 - 0.07 MPa.
• Test that the unit can start and stop in both foam
and rinse position
• Reinstall the cover on the unit
The following deliming interwals must be observed to
prevent lime building up in the unit, that can discon-
tinue operation of the unit
°dH
ppm
Time between Deliming
0-5
18-90
12 months
5-10
90-180
6 to 12 months
10-15
180-270
3 to 6 months
15-20
270-360
3 to 6 months
>20
>360
1 to 3 months

9.4. Coupling

It is recommended to lubricate all coupling parts
regularly (approx. once a month) with waterproof
grease to prevent leaks and damage of packings. If
the unit is equipped with a spray gun the piston of the
gun should also be lubricated.
In leaking quick couplings the packings should be
replaced.
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Yeti hpYeti pd

Tabla de contenido