Maintenance and servicing
Hydraulic oil
The oil level must be checked at intervals of 6 months. To fill up use a hydraulic oil in compliance with ISO VG 46
Removing air bubbles in the hydraulic system
Changing the seals can lead to air bubbles in the hydraulic system. To remove these, put the switch handle (H106)
in the LOWER position and then move the tow handle several times up and down.
Moving parts
The moving components of the drum transporting truck must be checked regularly for ease of movement and if
required relubricated with commercially-available lubricating grease.
In the event of damage and particular incidents that could influence the carrying capacity as well as after repairs
an extraordinary testing by a qualified person is to be carried out.
Declaration of conformity
EC Declaration of Conformity
Herewith we, the DENIOS AG, Dehmer Straße 58-66, D 32549 Bad Oeynhausen, declare that the product
complies with following guidelines.
Hydraulic drum pallet truck
Type:
Safe working load:
350 kg
EC Directives
Machinery directive 2006/42/EC
Harmonised standards applied
EN 1494
DIN EN 1757
EN 349
EN ISO 14121
EN 12100 -1,-2
Person responsible for documentation
DENIOS AG, AG, 04.01.2010
Mr. Dr. Ing. R. Adenstedt
Theodor Breucker
Head of engineering
- Board of governors -
Fasshubwagen
Seite 9 von 15 Seiten
Ausgabe 05/2010
158052