Manual editing of messages
The program mode pushbutton (4) can be used to manually change the message sequence of trigger inputs 7 to 12
and the corresponding zone set-up. Manual editing is not possible for the trigger inputs 1 to 6; these input
configurations must be uploaded from the PC to avoid abuse.
Manual editing of trigger inputs is done as follows:
•
Press the program mode pushbutton (4) and keep it depressed for more than 3 s. The program mode indicator
LED (5) will light up to indicate that the message manager is in the program mode.
•
Briefly press one of the pushbuttons (9), e.g. #11. The corresponding trigger indicator LED (8) will flash and the
(upper) trigger indicator LEDs 1 to 6 will indicate the stored zones for pushbutton #11. The message indicator
LEDs (7) will only indicate the messages related to pushbutton #11. Their place in the sequence is not indicated.
•
Use the pushbuttons (9) to toggle the zones 1 to 6 ON and OFF, thus indicating the new zone selection.
•
Press the monitor pushbutton (3) briefly to clear the present message sequence for the selected pushbutton (9).
Pressing the monitor pushbutton (3) once more causes the message indicator LED #1 to flash; subsequent
pressing causes the message indicator LEDs #2, 3, 4, etc. to flash. If the monitor pushbutton is pressed for more
than 3 s the message indicator LED that flashed is selected as the first message of a new sequence for the
selected pushbutton (9). In this way up to four messages can be selected in a random order to be part of that
announcement. After the fourth message no more messages will be accepted.
•
Press the program mode pushbutton (4) once again for more than 3 s to enter the new configuration data and to
exit the program mode.
•
Repeat the above procedure for any of the other pushbuttons (9).
•
If during this manual editing process a trigger input is activated, the unit will quit the program mode and the
requested announcement will be started.
•
If in the program mode no pushbutton is pressed for approx. 25 s, the unit will automatically resume its normal
working mode, without storing the new configuration data.