PLENA UNIVERSAL PRE-AMPLIFIER
MASTER
MASTER LINE
MIC OUT
Setting emergency, insertion or cascade
Eng
The functionality of the insertion/cascade/emergency input is determined with jumper JP301 and the 'Ins/Casc' switch at
the back of the unit.
Input/output used for
Insertion
Cascade
Emergency
Note
If you use the emergency option, the emergency volume can be set with VR301.
This volume is not affected by the master volume.
INS/CASC
INS/CASC/
OUT
OUT
EMG IN
Jumper JP301
OFF
OFF
ON
INS/CASC
SWITCH
DIR OUT 4
DIR OUT 3
S301
JP301
ON
OFF
EMERGENCY
VR301
EMERGENCY
CN303
LEVEL
Switch
INS
CASC
CASC
8
DIR OUT 2
DIR OUT 1