Saci pumps VG Serie Instrucciones De Instalación Y Manejo página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SD/SV Series Submersible Pumps
Installation
1. Check the following before beginning installation.
Insulation resistance measurement:
With the motor and cable (excluding the power supply cable) immersed in water, use a Megger to measure
the insulation resistance between ground and each phase of the motor, and again between each phase of
the motor. The Megger should indicate an insulation resistance of
making the measurement, keep the power supply cable off the ground.
An auxiliary pump is recommended to be kept on hand in case of emergency.
2. Installation-
! WARNING :
(1)
circumstances should cable be pulled
while the pump is being transported or
installed.
Attach a chain or rope to the grip and
install the pump.
(2) This pump must not be installed on its
side or operated a dry condition. Ensure
that it is installed upright on a secure
base.
(3) Install the pump at a location in the tank
where there is the least turbulence.
(4) If there is a flow of liquid inside the tank,
support the piping where appropriate.
Install piping so that air will not be
entrapped. If piping must be installed in
such a way that air pockets are
unavoidable, install an air release valve
wherever such air pockets are most likely
to develop.
(5) Do not permit end of discharge piping to
be submerged, as backflow will result
when the pump is shut down.
! WARNING :
(6)
have an automatic operating system
bump operating water level near the
minimum operating level as the automatic
cut-off switch incorporated inside the
motor will be activated. To avoid dry
operation, install an automatic operating
system, as shown in
safe operating water level.
(7) For automatic pumps, install the floats as
Fig-2.
shown in
if a floats switch touches the wall of the
water tank or the piping. Install the floats
so that this will not happen.
Under no
Non-automatic pumps,
Fig-1
and maintain a
The pump may not start
not less than 20mega ohms
off
Fig-1
H1: Lowest water level (Motor flange)
H2: Operating water level
This must be above the top of the motor
Operating Water Level
Stop Water Level
3
. While
on
Fig-2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vn serieDg serie

Tabla de contenido