GB
1 - SAFETY WARNINGS
CAUTION – to ensure personal safety it is important to follow
these instructions and keep them for future reference.
Read the instructions carefully before proceeding with installation. The design and ma-
nufacture of the devices making up the product and the information in this manual are
compliant with current safety standards. However, incorrect installation or programming
may cause serious damage to property or injury to those working on or using the sy-
stem. Compliance with the instructions provided here when installing the product is
therefore extremely important.
2 - INTRODUCING THE PRODUCT
MINIATURISED DOMOTIC CONTROL UNIT
The RX2H is a miniaturised control unit both for controlling power-operated awnings
and shutters and for the on/off control of lights, by means of pushbuttons or by radio
remote control. The control unit allows intelligent control of lighting levels, with the
addition of one or more by-wire light control points.
The RX2H control unit is able to recognise the first transmitter saved in the memory,
which may be of fixed or variable code type.
The control unit input logic will be unchanged in the "lighting" mode, while in the "motor
control" mode the input specifications are as follows:
COMBINATION
INPUT 1
INPUT 2
INPUTS 1 AND 2 SIMULTANEOUSLY
CODE
DESCRIPTION
Domotic control unit for the remote control of awnings, shutters or lights,
RX2H
with the addition of one or more radio remote lighting control points
TECHNICAL SPECIFICATIONS
AC power supply voltage
110V 50/60Hz
DC power supply voltage
Standby power
Power with outputs active
VAC output current
VAC output current
VDC output current
IP
Operating temperature
Sensitivity
Decoding
FIX/
Frequency
Number of transmitters
LIGHTING WIRING DIAGRAM
LED
INPUTS
PUSHBUTTON
230 Vac
1
2
Local inputs
-2 switches
or
- 2 pushbuttons
Ch1
Ch2
Live
230 Vac (L)
Neutral (N)
MOTOR WIRING DIAGRAM
OPEN
Local control
STOP
inputs
CLOSE
- 2 pushbuttons
STOP
Live
230 VAC
Neutral
STEPPING
Local control
(OPEN-STOP-
input
CLOSE-STOP)
- 1 pushbutton
Live
230 VAC
Neutral
FUNCTION PROVIDED
UP/STOP
DOWN/STOP
STEP-BY-STEP
MIN
TYPICALLY
-
250V 50/60Hz
110 V
-
-
0.3W
-
1.4W
5A/1250VA @ 250V
-
-
(Cos φ=1)
2A/500VA @ 250V
-
-
(Cos φ=0,4)
5A/150VA @ 30V
-
-
(resistive load)
-
20
- 20 °C
-
-
-108 dB
ROLLING CODE
-
433.92 MHz
-
-
SUPPLY
OUTPUTS
N
L
L
3
4
5
6
7
Ch1
Ch2
See table for
specifications
1
2
3
4
5
6
7
M
See table for
specifications
1
2
3
4
5
6
7
M
See table for
specifications
3 - PRELIMINARY CHECKS
WARNING - before installing the product, perform the following checks and in-
spections:
• Check that the intended mounting surface is solid and does not allow vibrations
• Use electrical connections suitable for the currents required
• Check that the power supply conforms to the values in the technical specifications
• Disconnect the power supply before proceeding with installation
• The system power supply line must include a circuit breaker device with a
contact gap allowing complete disconnection in the
conditions required by class III overvoltage
4 - DEVICE TYPE (LIGHTING OR MOTORS) SELECTION
WARNING: in motor control mode, the default operating timeout is 4 minutes.
To vary the operating time, adjust the timeout using the procedure provided
PH.
DESCRIPTION
WARNING: when this setting is changed, all the remo-
te controls will also be cleared from the memory.
1
Press and hold the control unit programming pushbutton.
The LED blinks once and the buzzer sounds.
Hold the control unit programming pushbutton. The control
unit LED blinks and the buzzer sounds again.
The control unit signals the operating mode selected by
means of a number of beeps and blinks. Whenever the
pushbutton is pressed again, the function will be changed
as follows:
1 beep = LIGHTING mode
2
2 beeps = MOTOR mode
The system will notify the user of the setting just made
by blinking the LED quickly and sounding the buzzer the
MAX
number of times equivalent to the mode selected every 2
seconds.
240V
To save the selected mode, press the control unit pro-
-
3
gramming pushbutton and hold it for more than 3 secon-
-
ds. The LED blinks and the buzzer sounds again.
5 - LIGHTING MODE
5.1 - PROGRAMMING OUTPUT 1
-
PH.
DESCRIPTION
+ 55 °C
Press the control unit programming pushbutton 3 times
-
1
in quick succession. The LED blinks three times and the
buzzer sounds 3 times every 2 seconds.
-
30
Hold the control unit programming pushbutton. The LED
2
blinks and the buzzer sounds again.
The control unit signals the operating mode selected by
means of a number of beeps and blinks. Whenever the
pushbutton is pressed again, the function will be changed
as follows:
1 beep = Monostable (active for as long as the key is held)
2 beeps = Bistable (status changes whenever the key is
3
pressed)
3 beeps = Timed (active for the time set)
The system will notify the user of the setting just made
by blinking the LED quickly and sounding the buzzer the
number of times equivalent to the mode selected every 2
seconds.
To save the selected mode, press the control unit pro-
4
gramming pushbutton and hold it for more than 3 secon-
ds. The LED blinks and the buzzer sounds again.
5.2 - PROGRAMMING OUTPUT 2
PH.
DESCRIPTION
Press the control unit programming pushbutton 4 times
1
in quick succession. The LED blinks four times and the
buzzer sounds 4 times every 2 seconds.
Proceed from point 2 of the previous section: Program-
2
ming output 1
EXAMPLE
>3s
x 1+
x 1
>3s
x 1+
x 1
x n
x n +
x n
>3s
x 1+
x 1
EXAMPLE
>3
x 3+
x 3
>3s
x 1+
x 1
x n
x n+
x n
>3s
x 1+
x 1
EXAMPLE
>4
x 4+
x 4