7 - REPLACEMENT OF THE HOSE
A
D
WARNING:
FOR SAFETY REASONS, THE HOSE MUST BE REPLACED ON THE BENCH.
Use a hose with dimension and pressure characteristics suited to the use.
(See table of characteristics).
1.
Remove the rubber stop and slowly let out the hose until the spring is completely released
(Figure A).
2.
Unscrew the turning connection (Figure B).
3.
Remove the two screws on the spring hub with a 10 mm spanner (Figure C).
4.
Remove the side where the spring is with a 10 mm spanner. Unwind the hose completely from
the drum. (Figure D).
5.
Remove the drum, unscrew the inside connection piece with the right size spanner and mount a
new hose (Figure E).
6.
Refit the winder by reversing the order of operations. Lubricate the holder and catch if
necessary.
7.
Go on as indicated at point 2 of the chapter 6 "Mouting the hose".
DO NOT PUT HANDS OR ANY OTHER THING INSIDE THE DRUM !
B
E
13
C