TECElux – senTouch
Programming of the TECElux sen-Touch electronic
The sen-Touch electronic can be programmed within the
first hour after connection to the power supply. After a
power failure, the most recently saved setting is retained.
A position on one of the two touch fields is assigned to
each configurable function.
Large touch field:
Position
Function
1
Default setting
2
Hygienic flush off
3
Hygienic flush 24 h
4
Hygienic flush 56 h
5
Hygienic flush 84 h
6
Hygienic flush 168 h
7
Hygienic flush 336 h
8
Hygienic flush 672 h
9
Illumination level 1 very bright
10
Illumination level 2 standard
11
Illumination level 3 dimmed
12
Illumination level 4 darker
13
Safety flush off
14
Safety flush on
= Default setting
Small touch field:
Position
Funktion
1
Recognition very short
2
Recognition short
3
Recognition standard
4
Subsequent odour extraction 5 min
5
Subsequent odour extraction 2 min
6
Subsequent odour extraction 1 min
7
Subsequent odour extraction off
8
Fan setting extra quiet
9
Fan setting standard
10
Fan setting power
11
Cleaning function om
12
Cleaning function off
13
Light activation 20 sec*
14
Light activation 2 min
15
Light activation 3 min
16
Light activation 4 min
17
Light activation 5 min
18
Light activation permanent*
= Default setting
* Function only for exhibitions
Procedure
How to program the sen-Touch electronic:
Touch the large or small touch field. After 10 seconds,
programming mode starts with a series of quick signal
tones.
After the start phase, a series of identical individual
signal tones can be heard. Count these – with the hand
on the button – until you reach the required function.
Then remove your hand; you hear a long confirmation
signal tone.
Example: Set hygienic flush to 84 hours.
. . . .
Start
1
2
Place your hand on
Count the individual
the large touch field
signal tones to the
required position
Cleaning function
When the cleaning function is activated, the touch field is
deactivated for 30 seconds (prerequisite: Function 11 of
the small touch field is selected).
Activate the cleaning function:
Simultaneously touch both touch fields for 7 seconds.
After this period, the previously configured functions are
automatically reset.
The cleaning function can only be activated in standard
operation – not during the programming phase.
Safety flush
If the safety flush is activated, a flush is actuated
2 minutes after a person was last detected in the
recognition range and a flush has not been actuated since.
Please use this function for public restrooms with cabins
only!
Manual actuation
A flush is also possible even if there is no power –
e.g. after a power failure: Pull the top glass plate up from
the wall and press the red actuating rod.
english
3
4
5
OK
Remove your
hand
3