Technical data
Parameters
Model
Dehumidifying capacity, max.
Operating temperature
Working range for relative humidity
Volume of airflow, max.
Electric connection
Power consumption, max.
Fuse (home)
Condensation tank
Refrigerant
Amount of refrigerant
Weight
Dimensions (HxDxW)
Minimum distance from walls of other objects
Sound pressure level LpA (1 m; complies with DIN 45635-01-KL3)
Circuit diagram
TUBE
ROOM
TEM.SENSOR
TEM.SENSOR
RT1
RT2
CN3
CN2
CN1
AP2
CN4
ST
HUMIDITY
SENSOR
B - 3
CN1
AP1
CN2
6BU
7BN
C2
2YE
SW
NO
COM
WATER
SWITCH
Operating Manual – Dehumidifier TTK 40 E
Values
TTK 40 E
14 l / 24 h
5–35 °C
30–100 %
100 m³/h
230 V / 50 Hz
340 W
3.15 A
3.5 l
R134a
75 g
10.5 kg
496 x 225 x 353 mm
A: Above: 45 cm
B: Behind: 45 cm
C: Side: 45 cm
D: Front: 45 cm
43 dB (A)
WH
BK
CN3
BU
RD
C1
K1
AC-L
4
N
3
COMP
N1
YEGN
1RD
4BU
SAT
3BU
5BK
R(M)
C
COMP.
9YEGN
S
PE
FAN
MOTOR
M1
YEGN
BN
PE
BN
L
BU
N
POWER
PLUG
PE