Predispose the condensate drain pipe with a positive slope
to the outside.
Convoy the condensate to the outside with a positive slope,
form a trap at the end if necessary.
4. CONTROL OF THE AIR VOLUME TO THE OUTLET GRILLES
The unit is prearranged to supply an external static pressure of about 7,5 Pa (7/9/12) and 10 Pa (16/18/22). Too high resistances
in the air distribution system can cause an exceedingly small air volume to the outlet grilles.
7/9/12
25,0
20,0
15,0
10,0
5,0
L 335m/h 4.9Pa
0,0
280,0
330,0
16/18
35,0
30,0
25,0
20,0
15,0
10,0
5,0
0,0
300
350
M 380m/h 5.9Pa
380,0
AIR FLOW VOLUME (m
L 450m/h 4.7Pa
400
450
500
AIR FLOW VOLUME (m
H 470m/h 7.5Pa
430,0
480,0
3
/ h)
H 620m/h 10Pa
M 540m/h 7.2Pa
550
600
3
/ h)
8
H = High fan speed
L = Low fan speed
M = Middle fan speed
650
700