Terminator
1.
Cut end of cable at angle to aid in piercing
grommet. Leave additional cable for
expansion loop.
4.
Slide expediter toward pipe and route
cable through support base entry.
7.
Cut off end of cable.
ECM-R-XP
TM
2.
Position RTD Sensor(s) in grommet (when
applicable). Do not pull from the sensor
end when routing through the expediter
assembly. Pull sensor from the lead wire
portion.
5.
Insert banding guide into expediter and
snap into place.
8.
Terminate cable with appropriate PETK
termination kit. Refer to PETK installation
instructions.
INSTALLATION PROCEDURES
3
3.
Insert cable into expediter. If mounted on
bottom or side of pipe, punch out weep hole.
6.
Mount expediter to pipe using pipe band.
Do not band over cable.
9.
Push excess cable and RTD cable back
through expediter. Tighten cap securely.
Tape cable expansion loop to pipe.