Application
Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit with pressure reducing
valves
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
- Scalding protection possible by fitting a handle
rotation stop (see replacement parts on page 2,
order no. 46 375).
• Water connection
Notes
• An access panel must be provided for access to the
hose connections.
• Major pressure differences between cold and hot
water supply should be avoided.
Installation
Layout dimensions to establish centers and proper
clearences, see dimensional drawing on page 1.
Flush piping system prior and after installation of
faucet thoroughly!
Installing faucet body, see page 3, fig. [1].
- Fit faucet body (A) with mounting set (A1).
Installing spout, see page 3 figs. [2], [3] and [4].
1. Fit shank (B) with mounting set (B1), see fig. [2]
and [3].
2. Fit spout (C) to the shank (B) and tighten
set screw (D) with 3mm allen wrench, see fig. [4].
approx. 24 l/min or 6.3 gpm
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - Right hand
hot - Left hand
English
Connecting the faucet, see page 3 figs. [5] and [6].
1. Fit hose (E) to shank (B) with 29mm open-ended
wrench and with 24mm open-ended wrench to
pipe (G).
2. Fit hoses (H) to pipes (J) with 24mm open-ended
wrench.
The cold water supply should be connected on the
right, the hot water supply on the left side.
Open cold and hot water supply and check
connections for leakage.
Operation
Pull lever
Press lever down
Turn lever right
Turn lever left
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off cold and hot water supply!
I. Replacing the cartridge, see page 3, fig. [7].
1. Lever out plug (K).
2. Loosen set screw (L) with 3mm allen wrench and
pull off lever (M).
3. Unscrew cap (N).
4. Remove screws (O).
5. Replace complete cartridge (P).
Assemble in reverse order.
Observe the correct installation position.
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (O) and tighten
evenly and alternately.
II. Unscrew and clean flow straightener (46 728), see
page 2.
Assemble in reverse order.
Replacement parts, see page 2 ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the
Limited Warranty supplement.
= open (water flow)
= closed
= cold water
= hot water
4