Stopping
the
Engine
1.
Turn OFF and unplug all electrical loads from
generator
panel receptacles.
NEVER start or stop engine
with electrical
devices plugged in and turned
ON.
2.
Let engine run at no-load
for several minutes
to
stabilize internal
temperatures
of engine and generator.
3.
Turn engine off according
to instructions
given in the
engine operator's
manual.
4.
Move fuel valve to"Off"
position.
RECEPTACLES
[
CAUTION
1
. NEVER attempt to power a device requiring more amperage
than generator
or receptacle can supply.
. DO NOT overload the generator. See "Don't Overload
Generator
'_.
1:201240 Volt AC, 20 Amp,
Locking
Receptacle
Use a NEMA L14-20
plug with this receptacle.
Connect
a
4-wire
cord set rated for 250Volt
AC loads at 20Amps
(or
greater)
(Figure 5).You can use the same 4-wire
cord if you
)lan to run a 120Volt
load.
4-Wire
Cord
Set
Ii J
(Neutral)
NEMA L 14-20
Y (Hot)
i
X (Hot)
Ground (Green)
This receptacle
powers
I20/240VoItAC,
60 Hz, single
phase loads requiring
up to 3,500 watts
of power
(3.5 kW)
at 14.6 Amps for 240Volts
or two independent
120Volt
loads at 14.6 Amps each.The
outlet
is protected
by
push-to-reset
circuit breakers.
120 Volt A¢,
20 Amp,
Duplex
Receptacles
Each duplex receptacle (Figure 6) is protected
against
overload by a push-to-reset
circuit breaker.
@
@
Use each receptacle
to operate
120Volt AC, single-phase,
60 Hz electrical
loads requiring
up to 1,750 watts
(1.75 kW) at 14.6 Amps of current.
Use cord sets that are
rated for 125 Volt AC loads at 15 Amps (or greater).
COLD WEATHER
OPERATION
Under certain
weather
conditions
(temperatures
below
40°F [4°C] combined
with high humidity),
your generator
may experience
icing of the carburetor
and/or
the
crankcase
breather
system.To
reduce
this problem,
you
need to perform
the following:
I.
Make sure generator
has clean, fresh fuel.
2.
Open
fuel valve (turn valve to open
position).
3.
Use SAE 5W-30 oil (see engine operator's
manual).
4.
Check
oil level daily or after every eight (8) hours of
operation.
5.
Maintain generator
following "Maintenance
Schedule"
in engine operator's
manual.
6.
Shelter
unit from elements.

Publicidad

loading