ADVANCED PROGRAMMING
GB
7.6
DISPENSING TYPE
How to change
the setting
NO
Press this button to go to the
next screen
7.7
UV LAMP. ALARM
How to change
the setting
NO
Press this button to go to the
next screen
7.8
FILTER ALARM
How to change
the setting
NO
Press this button to go to the
next screen
Lets you choose water dispensing mode by preset LARGE/SMALL doses (value
?
0) or by pulse dispensing or by pressing the dispensing buttons (value 1). The
factory-set value is (0).
If pulse dispensing is selected (value 1), SMALL and LARGE dose settings are
disabled (although the dose settings remain stored in the system's memory).
YES
?
This is a warning that appears when the UV lamp in the dispensing area (or
the UV lamp on the inlet filter, if installed) is almost worn out.
The factory-set value is (0), i.e., no alarm message is displayed.
To enable the "UV LAMP" alarm enter a value on the timer from 0 to 2000 days.
Consider that the UV lamp in the dispensing area (optional) has an average
lifetime of 250 days (6000 hours). A warning message informing that the lamp
will soon need replacement appears when 90% of its preset lifetime has lapsed.
YES
?
YES
Buttons 1-2 for choosing the dispensing mode:
(0) Dispensing by preset doses
(1) Dispensing by pressing the buttons
Press this button to confirm.
Buttons 1-2 for setting the interval (in hours) between lamp
replacements.
Press this button to confirm.
Warning! To complete the operation you must reset the counter as
described in screen 7.11
Buttons 1-2 for setting the quantity of supplied water (litres) between
filter replacement.
Press this button to confirm.
Warning! To complete the operation you must reset the subtotal litre
counter as described in screen 7.13
11