Descargar Imprimir esta página

Viking VINV600 Guia De Inicio Rapido página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Model VINV600 Ventilator Kit
VENTILATOR KIT INSTALLATION
1. Choose the correct VENTILATOR MOUNTING PLATE for your hood series. (VBCV53638 and VBCV54238 will only be
shipped with the 050722-000 mounting plate.)
2. Attach DAMPER to ventilator mounting plate, as shown. Use three (3) HEX SCREWS. Note: Damper FLANGE to be
captured by screw heads.
3. Apply (4) NEOPRENE WASHERS (supplied) to each of the mounting plate STUDS.
4. Attach BLOWER to MOUNTING PLATE with (4) 10-24 HEX NUTS.
5. Attach blower / mounting plate assembly to the hood's (4) THREADED STUDS with (4) 10-24 HEX NUTS.
6. Plug blower's POWER CORD into RECEPTACLE inside the hood.
7. Wrap wires with wire tie (provided).
Ventilator configuration using
mounting plate 020970-000
THREADED
TOP OF HOOD
STUDS
DAMPER
RECEPTACLE
MOUNTING
PLATE
STUDS
BLOWER
POWER
CORD
HEX NUTS
Ventilator configuration using
mounting plate 020971-000
THREADED
STUDS
DAMPER
HEX
SCREWS
FLANGE
RECEPTACLE
NEOPRENE
WASHERS
POWER
CORD
TOP OF HOOD
HEX
SCREWS
FLANGE
MOUNTING
PLATE
STUDS
NEOPRENE
WASHERS
BLOWER
HEX NUTS
2