FOR YOU R SAFETY - STARTI NG U P YOU R PE LLET G RI LL
C A U T I O N
•
DO NOT touch the ignitor rod.
C A U T I O N
The main power switch
the control panel and to the grill components only. When
servicing the control panel or any parts ensure that the
power supply cord is disconnected to avoid a shock
hazard.
SAFETY FEATURES BUILT INTO THE CONTROL
SOFTWARE
The control system is equipped with safety features to help
keep the smoker in the desired operational range. The fea-
tures are as follows:
Flameout Watch: Unless the system is in the Preheat cycle
or the Shutdown cycle, the control system will activate the
Flameout Watch cycle, if the temperature measured by the
probe inside the cooking chamber is lower than 100°F (38°C).
The system tries to re-establish combustion and achieve the
heat setting for 20 minutes. If, after 20 minutes has passed,
and the measured temperature remains below 100°F, the sys-
tem will display error code ER5. The system will also activate
the Shutdown cycle. The Shutdown cycle will shut off all the
electrical components and turns off the unit in an orderly and
controlled manner.
Overheat Watch: Unless the system is in Shutdown cycle,
the control system will activate the Overheat Watch cycle if
the cooking chamber temperature is above 700°F (371°C).
If the cooking chamber temperature measured by the probe
remains above 700°F (371°C) for 3 minutes, the control sys-
tem displays error code ER6. The Shutdown cycle will also be
activated. The Shutdown cycle will shut off all the electrical
components and turns off the unit in an orderly and controlled
manner.
Standby Mode: If the grill is powered on, but the control knob
is not set to any smoking or grilling target temperature, the
control system shifts into the standby mode. If the system re-
mains idle for 5 minutes in the standby mode with no inputs
from the consumer, the system will shutdown and power off.
will shut the power off to
32
OK LAHO M AJ O ES. CO M