MANUAL SWITCH
INDEX
PINS
SAVING
TEMPERATURE
SELECTOR
DESCRIPTION:
The chronothermostat ERA is a friendly analog programmable room thermostat. It
is possible to set different temperatures at different periods of time.
Features
- 2 independent temperatures that can be programmed (Confort
Saving
).
- Daily or weekly programm (according to versions)
- Programming is very confortable as it can be done outside the base over a
dial with pins.
- Can be used to control heating or air condition.
- Minimum period between temperature levels: 15 minutes for daily version
and 2 hours for weekly version
- Temperature range of adjustment:
Confort: +10 ºC to +40 ºC aprox.
Saving: 0 ºC to +25 ºC aprox.
- Manual override (Confort, automatic or Saving)
- Battery level test.
ATTENTION:
Electrical devices must be installed and assembled by authorized installer. Before
connecting, be sure that the conductors are not under voltage. The device is
internally protected against interference by a safety device.
INSTALLATION
Surface mounting or flush mounting. To fit the device, remove the fixing base by
pressing the push button of the lower part. Fix the base by using the attached
screws. To insert ERA into the base, first introduce the two upper guides of the
base in the slots of the device and press on the lower part until the flange is fitted
in the apropiate existing hole.
CONNECTION
Connect according with the following schema:
1
AIR CONDITION
PLACING AND REPLACEMENT OF BATTERIES
The device is powered by two alkaline batteries LR06(AA) of 1,5 V (not included).
Observe the polarity indicated in the housing of batteries. The aproximate batteries
duration is one year.
Please, put used batteries in aproppiate batteries container.
The device incorporates a push button to test if the batteries still have good level.
If after pressing it, the LED indicator do not light, then replace the batteries.
MANUAL KNOB
LED
DIAL
Chronothermostat
CLOCK
HANDS
35
20
30
15
25
10
20
10
5
15
CONFORT
TEMPERATURE
SELECTOR
2
3
HEATING
BATTERY TEST
PUSH BUTTOM
BATTERY COVER
FIXING BASE
CLOCK SETTING
Turn the dial clockwise so the index indicates the real time. In the weekly version, the
day of the week shall also be adjusted. The hours handles shall also indicates the
real time.
PROGRAMMING
Move up all the pins. Move down the pins corresponding with the hours when the
temperature should be the confort one (
temperature (
MANUAL KNOB
3 positions.
.- Permanent in Confort temperature.
.- Automatic. According with the programing of the pins in the dial.
.- Permanent in Saving temperature.
and
TEMPERATURE ADJUSTMENT
Temperatures can be adjusted by using the selectors corresponding with Confort
(
) and Saving (
TECHNICAL FEATURES
Power supply:
Switching capacity:
Battery duration:
Action type:
Temperature accuracy:
Confort temperature range:
Saving temperature range:
Operting temperature:
Protection class:
Protection type:
Pollution situation:
DIMENSIONS:
43
37
) and the rest of the time the saving
) is selected.
) temperatures.
2 alkaline batteries LR06(AA) 1,5 V
5 (1) A 250 V∼
1 year roughly
1B, 1S, 1T and 1U
± 1 ºC
10 ºC to 40 ºC aprox.
0 ºC to 25 ºC aprox.
-10 ºC to 45 ºC
II according to EN 60335 when mounting as
intended.
IP 40 according to EN 60529
Normal
11.5
30
26
17
4
36
11
37.5
MOUNTING DIMENSIONS
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61
Teléfono: +34 91 5672277;
E-mail: info@ orbis.es
http://www.orbis.es
142
35
20
30
15
25
10
20
10
5
15
A016.73.52877
E-28020 MADRID
Fax: +34 91 5714006

Publicidad

loading