HOW THE APPLIANCE OPERATES
This appliance has 3 operating modes (AUTO COMFORT, CONTROL , CONTINUOUS) as well as
various additional functions.
"ON/STAND-BY":
switch on / standby (stop); button A.
Press button (A) to start the appliance or to put it on standby. The digital screen lights up and the
device starts directly in AUTO mode.
SMART OPERATION MODES:
Selection of operating modes using button B. Select one of the three modes by repeatedly pressing
the button B.
1 - AUTO COMFORT MODE:
The appliance will automatically adapt the humidity level according to the room temperature for
optimal comfort at home.
In order to reach the optimal comfort in the room you are in, this setting takes in account the room
temperature and calculates the optimal humidity level.
When the humidity in the room is lower than the program, the appliance operates at maximum speed.
When the humidity in the room is reached, the appliance stops working and re-starts at maximum
speed as soon as the humidity in the room is lower than the program.
The humidity and the temperature in the room are measured every 60 seconds.
Temperature ≤19 °C 20-21°C 22-23°C 24-25°C 26-27°C 28-29°C 30-32°C 33-36°C
Humidity
65 %
target % RH
You can select the warm mist function with Auto comfort mode.
2 - CONTROL MODE:
• Humidity level: Button B for adjusting the required (target) humidity level;
Select the required humidity level by pressing button B several times.
The humidity level displayed is the required level that you have set (between 45% and 90% RH).
You can select the warm mist function with Control mode.
• Mist volume: Button C
Select the required mist volume by pressing button C several times. There are three speeds available.
You can adjust the mist volume in order to reach faster the required level of humidity.
PLEASE NOTE: This setting cannot be used for AUTO COMFORT mode.
3 - CONTINUOUS MODE:
Press the Button B, until the continuous mode, "Co" appears on the digital screen.
The appliance operates until reaching 90% RH (safety limit) or until the reservoir is empty. The mist
is permanently emitted and you can adjust the mist volume.
The appliance will stop working automatically when the humidity level of the room is over 90% RH
and it will re-start when the humidity level of the room measured is 80% RH.
WARNING: In the continuous operating mode, the humidity in the room can reach very high levels
that are not beneficial to health and can damage certain objects. The recommended optimal humidity
level is between 50 and 60% RH.
• Mist volume: Button C
Select the required mist volume by pressing button C several times. There are three speeds available.
ADDITIONAL FUNCTIONS:
• TIMER: Button D for programming the automatic stop of the appliance.
Select the number of hours that you want the appliance to run for (from 1 to 12 hours) before
the appliance automatically stops, by pressing button D several times. The display will show the
remaining time. Anytime, you can change the timer, increasing the time by pressing the button, until
12hours.
• WARM MIST function Button E: Heated mist for anti-bacterial and turbo effects:
Press button E to start or stop the "Warm Mist" function. On the screen, the red pictogram appears
or disappears. After 10 minutes of use, the mist becomes warm.
60 %
55 %
50 %
45 %
40 %
19
≥37°C
35 %
30 %
25 %
EN